Hybrid direct power/current control using feedback linearization of three-level four-leg voltage source shunt active power filter
نویسندگان
چکیده
Introduction The excessive use of power electronic equipments, which represent nonlinear loads, in a distribution network has caused many disturbances in the quality of power such as harmonic pollutions, unbalanced load currents, and reactive power problems. As a result poor power factor, weakening efficiency, overheating of motors and transformers, malfunction of sensitive devices etc. are encountered [1–3]. Conventionally, a passive power filter which consists of passive elements is used to provide harmonic filtering as an economical and effective filtering device. However it has shortcomings such as fixed compensation performance, bulk in size and resonance troubles [4–7]. Important kinds of passive power filters and their configurations are discussed in [4]. To overcome the shortcomings of passive power filters and to mitigate the power pollution in networks caused by the nonlinear loads, an active power filter (APF) was established in around 1970s [8–10]. APFs are previously not implemented in power networks, because of unavailability of high speed power switching devices. Recently the power electronic development spurred the interest in IGBTs, MOSFETs, etc. [8] and then APFs are developed incorporating power electronics technology to support the needs of industry. Shunt, series, and hybrid configuration are the three main types of three-phase, three-wire active power filters and their merits and demerits are discussed in [4]. For medium to high power applications the multilevel converters are the most attractive technology. Indeed, multilevel converters have shown some significant advantages over traditional two-level converters [9–12]. The main advantages of the multilevel converter are a smaller output voltage step, lower harmonic components, a better electromagnetic compatibility, and lower switching losses [9–12]. In the recent time, the use of multilevel inverters is prevailing in medium-voltage active power filters without using a coupling transformer [13–17]. In several areas, power is distributed through three-phase fourwire system and traditional APF is inadequate for harmonics compensation and power factor correction. To overcome this shortage, a three-phase four-wire SAPF has been introduced in the 1980s [18–22]. Basically there are two main kinds of three-phase, four-wire SAPF depending on their connection to the neutral wire. In the first kind the neutral wire is connected to the midpoint of the DC-link capacitors. In [23,24], this approach was studied where the inverter was operating as an active power filter. However, although it is simple in terms of topology, this approach is not suitable for SAPF 630 M. Bouzidi et al. / Electrical Power and Energy Systems 61 (2014) 629–646 application, for the following reasons [25,26]: (1) insufficient DClink utilization, (2) high ripple on DC-link capacitors, (3) problem of DC-link capacitor voltages balance. In the second type the neutral wire is connected to the additional fourth leg, this topology has been shown to be a solution for inverters operating in three-phase four-wire systems and it offers full utilization of the DC-link voltage and lower stress on the DC-link capacitors [26]. Various control strategies have been proposed to control gridconnected DC/AC converters, a classic control usually based on grid voltage [27,28] or virtual-flux [29] oriented vector control (VOC or VFOC) scheme. This scheme decomposes the AC current into active and reactive power components in the synchronously rotating reference frame. Decoupled control of instantaneous active and reactive powers is then achieved by regulating the decomposed converter currents using proportional integral (PI) controllers. One main drawback for this control method is that the performance highly relies on the completeness of current decoupling, the accurate tuning of PI parameters, and the connected grid voltage conditions. Based on the principles of the well-known direct torque control (DTC) [30,31] of AC machines, an alternative control approach, namely, direct power control (DPC) was developed for the control of grid-connected voltage-sourced converters [32,33]. Similar to the traditional DTC, lookup table direct power control (DPC-LUT), as the name indicates, selects the proper converter switching signals directly from an optimal switching table on the basis of the instantaneous errors of active and reactive powers, and the angular position of converter grid voltage [33] or the virtual flux vector. This later result from the integration of converter grid voltage measured with voltage transducers [34] or estimated based on the DClink and the converter switch states [34]. The main disadvantage of DPC-LUT is the variation of switching frequency, which generates an undesired broadband harmonic spectrum range and makes it pretty hard to design a line filter. These disadvantages can be effectively overcome by using space vector modulation (SVM) algorithm to replace the traditional switching table. The combination of SVM and traditional DPC forms the space vector modulation direct power control (SVM–DPC) [35]. Indeed the traditional two dimensional SVM algorithms only can be used to control converter connected to power system with balanced voltage/current where the homopolar component in Concordia transformation is equal to zero. In the four-wire system distribution, the case of unbalanced voltage is taken in consideration; therefore, the homopolar component is not equal to zero. Thus, three dimensional space vector modulation (3DSVM) algorithms must be taken into account in order to generate the desired signal. In [25,26], 3DSVM schemes are analyzed for a four-leg twolevel voltage source inverter. Authors in [23,24] have presented a modulation scheme for a three-level inverter as an active power filter in three-phase four-wire systems where hysteresis modulation was designed in a three-dimensional domain. However, 3DSVM for a four-leg three-level inverter has not yet been studied in stationary reference frame. A novel algorithm of space vector modulation for a four-leg three-level inverter is proposed in this paper. The effectiveness of the proposed modulation algorithm, and the advantages of the proposed topology over conventional ones, are discussed and verified with simulation results with SAPF system. Commonly, the abovementioned control techniques are based on traditional PI control. In order to improve the performance of three-phase four-leg SAPF, various nonlinear control strategies have been reported in the literature. The proposed control strategies include among others sliding mode control [36], passivity control [37], nonlinear optimal predictive control [38] and H1 control [39]. In this paper, a nonlinear control strategy based on the feedback linearization associated to hybrid direct power/current control with 3DSVM (DP/CC-3DSVM) is applied to three-phase three-level four-leg SAPF in order to improve its performances. It is well known that feedback linearization technique is a control method which aims to eliminate the nonlinearity of the system by using the inverse dynamics [40]. It has been applied successfully to control the three-level neutral point clamped (NPC) boost converter [41], three-phase AC/DC PWM converters [42] and three-level three-phase shunt active power filter [43]. As a result, good performances have been reported and the nonlinear control law was able to reduce the influence of parametric variations, utility disturbances, and DC load shedding [41]. This paper is organized as follows. In Section ‘Four-leg shunt active power filter’, the configuration of four-leg SAPF is presented and the system model is developed. In Section ‘Control of threelevel four-leg compensator’, the feedback linearization associated to the DP/CC-3DSVM is investigated. The nonlinear controllers are synthesized and the three-level 3DSVMwith balancing capability are presented also in this section. In Section ‘Simulation results’, the performances of controlled system are verified by simulation results. Finally, in Section ‘Conclusion’ some conclusions are established. Four-leg shunt active power filter System description The basic compensation principle of the four-leg SAPF is shown in Fig. 1. The main task of the four-leg SAPF is to reduce harmonic currents and to ensure reactive power compensation. Ideally, the four-leg SAPF needs to generate just enough reactive and harmonic current to compensate the nonlinear load harmonic in the line. The resulting total current drawn from the AC main is sinusoidal and balanced. The compensated neutral current is provided through a fourth leg allowing a better controllability than the three-leg with split-capacitor configuration. The main advantage of the four-leg configuration is the ability to suppress the neutral current from the source without any drawback in the filtering performance. Mathematical model of the three-level four-leg SAPF The switching functions are defined as Fij where i e {a, b, c, n} is the phase and j e {0, 1, 2}is the voltage level. Fij takes value ‘‘1’’ if iphase is connected to voltage level j and ‘‘0’’ otherwise; these switching functions can be expressed as: Fx2 1⁄4 Sx2Sx1 Fx1 1⁄4 Sx2 Sx1 x 1⁄4 a; b; c or n Fx0 1⁄4 Sx2 Sx1 ð1Þ The instantaneous AC converter phase to neutral voltages vFa, vFb and vFc can be expressed in terms of switching functions and DC-link voltages capacitors as given by: vFa vFb vFc 2 64 3 75 1⁄4 Fa2 Fn2 Fa1 Fn1 Fa0 Fn0 Fb2 Fn2 Fb1 Fn1 Fc0 Fn0 Fc2 Fn2 Fc1 Fn1 Fc0 Fn0 2 64 3 75 vC2 þ vC1 vC1 0 2 64 3 75 ð2Þ The mathematical equations which govern the behavior of the AC-side of SAPF are: diFa dt 1⁄4 1 LF ðvFa va RFiFaÞ diFb dt 1⁄4 1 LF ðvFb vb RFiFbÞ diFc dt 1⁄4 1 LF ðvFc vc RFiFcÞ ð3Þ
منابع مشابه
A Novel Reference Current Calculation Method for Shunt Active Power Filters using a Recursive Algebraic Approach
This paper presents a novel method to calculate the reference source current and the referencecompensating current for shunt active power filters (SAPFs). This method first calculates theamplitude and phase of the fundamental load current from a recursive algebraic approach blockbefore calculating the displacement power factor. Next, the amplitude of the reference mains currentis computed with ...
متن کاملDesign and Control of a Novel hybrid Active Power Filter based on Load Harmonic Currents Separation with the aim of DC-link voltage minimization in voltage source converter
This paper proposes a new hybrid active power filter, including voltage source converter (VSC) based active power filter and Thyristor Controllable LC Passive Filter (TCLC-HAPF) for eliminating harmonic load current components and compensating reactive power. This new structure which is based on the separation of high and low-frequency components of load current idea can reduce the drawbacks of...
متن کاملImproving the performance of UPQC under unbalanced and distortional load conditions: A new control method
This paper presents a new control method for a three-phase four-wire Unified Power Quality Conditioner (UPQC) to deal with the problems of power quality under distortional and unbalanced load conditions. The proposed control approach is the combination of instantaneous power theory and Synchronous Reference Frame (SRF) theory which is optimized by using a self-tuning filter (STF) and without us...
متن کاملA Hybrid Control Method for Stable Operation of Active Power Filters in Three-Phase Four-Wire Networks
The main goal of this study is the use of Lyapunov’s stability theory to a three-phase four-wire shunt active power filter (SAPF), since this method has been applied effectively to other areas of converter. The dynamic model of the SAPF is first established, after that, a combination of fuzzy tracking control and Lyapunov function is suggested in order to impose a desired transient waveform on ...
متن کاملComparative Power Quality Analysis of Different DSTATCOM Topologies
This paper presents the three topologies of three-phase four-wire DSTATCOM for reduction of harmonics, reactive power compensation, increasing power factor, which occur due to a nonlinear load, environment problem and polluted grid. The performances of the above topologies have been compared for the magnitude of source current, power factor improvement, DC-link voltage regulation, and total har...