P 242 Contrast sensitivity in patients with different types of multifocal iols (monocular vs binocular)

نویسندگان

  • H. Azevedo
  • C. Gonçalves
  • E. Cardoso
  • C. Lobo
  • J. Mira
  • E. Leite
چکیده

m Implantation of posterior ch.unber lenses (intmcalar lens = IOL) is an established method to replace opaque lenses. Prefered positioning of implanted lenses is in the capsular bag. either with or without touching the posterior capsule. Purpose of the present study is to determine the real position of the implanted lens in relation to the posterior capsule and to measure a possible distance between IOL and posterior capsule by Scheimpflug-photography. Method: 62 eyes of 50 patients with uncomplicated senile cataract underwent pbacoemulsification and implantation of a posterior chamber lens during a period of 6 months. Postoperatively the position of the IOL was measured by Scheimpflug-photography. &&& Out of 62 pseudophacic eyes of 50 patients 48 photos were reproducible. 33 photos showed a measurable distance between posterior IOL and posterior capsule. In 15 photos the posterior IOL touched the posterior capsule. Conclusion: Against general assompt~on that the IOL normally touches the posterior capsule our results show that only about 30% of implanted posterior chamber lenses touch the posterior capsule. P240 A new coating method to improve intraocular lenses tolerance Puroose. Several attempts to trnprove the intraocular lenses tolerance by surface modification had been tried A new method of crosslinked heparin grafting is presented. Methods. A modified heparin 1s crosslinked on a pretreated PMMA surface. Heparin grafted clnto the surface is equivalent to a free short length chain An analysis of the surface has been carrred out by ESCA (electron spectroscopy for chemical analysrs). ReSultS The thrckness of the treat'nent was about 3 to 5 nm. The treated lenses were found biocompatible The coating was found mechamcally stable but also resistant to pH variation and to washing As antr-thrombogenic sites were used to graft the heparrn, the coating should not exhibit any ant+-thrombogenic effect In vitro experiments demonstrated that short length heparin chatns rnhrbrt fibroblasts growth factor activitya. Undergoing exoenments and clinical trials wc?re desraned to confirm these hypotheses. Results of these tests. will be presented. Conclusions: A new method has been developped to crosslinked heparin on lenses. Other properties than anti-inflammatory ones are expected from this new technique of heparin grafting. Experiments are underway to dernontrate them. Purpose: To investigate ocular biocompatibility of a new HEMA (hydroxyethylmetacrylate) foldable IOL. Material and methods: 16 albino rabbits underwent extracapsular lens extraction in the right eye, under general anesthesia, and were followed for one year: 6 rabbits were implanted with a 6mm HEMA IOL …

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prospective evaluation of visual outcomes with three presbyopia-correcting intraocular lenses following cataract surgery

PURPOSE To compare the visual acuity and quality of vision achieved with three widely-used intraocular lenses (IOLs) in subjects with bilateral cataracts. PATIENTS AND METHODS This three-arm, parallel, prospective, partially masked, single-surgeon study randomized 78 subjects to receive bilateral Crystalens® Advanced Optics (AO) accommodating IOLs, AcrySof® IQ ReSTOR® +3.0 multifocal IOLs, or...

متن کامل

Visual outcome and optical quality after bilateral implantation of aspheric diffractive multifocal, aspheric monofocal and spherical monofocal intraocular lenses: a prospective comparison.

AIM To evaluate the visual function after bilateral implantation of aspheric diffractive multifocal Tecnis ZMA00, aspheric monofocal ZA9003 versus spherical monofocal Akreos Adapt intraocular lenses (IOLs). METHODS Tecnis ZMA00, Tecnis ZA9003 or Akreos Adapt IOLs were bilaterally implanted in 180 eyes from 90 patients. The following parameters were assessed 3 months postoperatively: monocular...

متن کامل

Bilateral implantation of asymmetrical diffractive multifocal intraocular lenses.

OBJECTIVE To evaluate visual results after bilateral implantation of multifocal intraocular lenses (IOLs) with asymmetrical light distribution for the far and near focus. METHODS Twenty-nine patients underwent bilateral implantation of silicone-optic, foldable, diffractive IOLs in a prospective, 2-center, noncontrolled interventional study. Each patient had a distant-dominant multifocal IOL i...

متن کامل

Visual Results Following Implantation of a Refractive Multifocal Intraocular Lens in One Eye and a Diffractive in the Contralateral Eye

Objectives To assess the visual outcomes in patients who underwent cataract surgery with multifocal intraocular lens (IOL) implantation using a "mix and match" approach. Materials and Methods Twenty patients (40 eyes) were involved in this prospective, nonrandomized study. Refractive multifocal IOLs (ReZoom NXG1) were implanted in patients' dominant eyes and diffractive multifocal IOLs (Tecni...

متن کامل

Prospective study of bilateral mix-and-match implantation of diffractive multifocal intraocular lenses in Koreans

BACKGROUND To evaluate monocular and binocular visual outcomes for near, intermediate, and far distance in patients implanted with diffractive multifocal intraocular lenses (IOLs) with different add power contralaterally. METHODS This is a prospective contralateral study. Two diffractive multifocal IOLs with different added power were implanted bilaterally in twenty patients. TECNIS® ZKB00 (+...

متن کامل

Postoperative wavefront analysis and contrast sensitivity of a multifocal apodized diffractive IOL (ReSTOR) and three monofocal IOLs.

PURPOSE To compare visual acuity, total and high order wavefront aberrations (coma, spherical aberration, and other terms of high order aberration), and contrast sensitivity in 105 eyes implanted with 4 different types of intraocular lenses (IOLs) (1 multifocal apodized diffractive IOL and 3 monofocal IOLs). METHODS A prospective study comparing four types of IOLs (Alcon ReSTOR [50 eyes], Alc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Vision Research

دوره 35  شماره 

صفحات  -

تاریخ انتشار 1995