Sustained reduction of in-stent neointimal growth with the use of a novel systemic nanoparticle paclitaxel.
نویسندگان
چکیده
BACKGROUND Paclitaxel (PXL)-eluting stents in animals cause incomplete healing and, in some instances, a lack of sustained suppression of neointimal growth. The present study tested the efficacy of a novel systemic delivery nanoparticle PXL for reducing in-stent restenosis. METHODS AND RESULTS A saline-reconstituted formulation of PXL stabilized by albumin nanoparticles (nPXL) was tested in 38 New Zealand White rabbits receiving bilateral iliac artery stents. Doses of nPXL (1.0 to 5.0 mg/kg) were administered as a 10-minute intra-arterial infusion; control animals received vehicle (0.9% normal saline). In a follow-up chronic experiment, nPXL 5.0 mg/kg was given at stenting with or without an intravenous 3.5-mg/kg repeat nPXL dose at 28 days; these studies were terminated at 3 months. At 28 days, mean neointimal thickness was reduced (P< or =0.02) by doses of nPXL > or =2.5 mg/kg with evidence of delayed healing. The efficacy of a single dose of nPXL 5.0 mg/kg, however, was lost by 90 days. In contrast, a second repeat dose of nPXL 3.5 mg/kg given 28 days after stenting resulted in sustained suppression of neointimal thickness at 90 days (P< or =0.009 versus single dose nPXL 5.0 mg/kg and controls) with nearly complete neointimal healing. CONCLUSIONS Although systemic nPXL reduces neointimal growth at 28 days, a single repeat dose was required for sustained neointimal suppression. Thus, this novel systemic formulation of PXL may allow adjustment of dose at the stent treatment site and prove to be a useful adjunct for the clinical prevention of in-stent restenosis.
منابع مشابه
Paclitaxel balloon coating, a novel method for prevention and therapy of restenosis.
BACKGROUND Drug-eluting stents have shown promising antirestenotic effects in clinical trials. Non-stent-based local delivery of antiproliferative drugs may offer additional flexibility and also reach vessel areas beyond the immediate stent coverage. The aim of the present study was to evaluate a novel method of local drug delivery based on angioplasty balloons. METHODS AND RESULTS Stainless ...
متن کاملEffects of oral prednisone after stenting in a rabbit model of established atherosclerosis.
OBJECTIVES The aim of this study was to compare the effects of systemic prednisone in combination with a bare-metal stent (BMS) or a paclitaxel-eluting stent (Taxus, Boston Scientific Corp., Natick, Massachusetts) on neointimal inhibition and vessel healing in an atherosclerotic rabbit model. BACKGROUND Inflammation plays a critical role in neointimal formation after coronary artery stenting....
متن کاملChronic arterial responses to polymer-controlled paclitaxel-eluting stents: comparison with bare metal stents by serial intravascular ultrasound analyses: data from the randomized TAXUS-II trial.
BACKGROUND Polymer-controlled paclitaxel-eluting stents have shown a pronounced reduction in neointimal hyperplasia compared with bare metal stents (BMS). The aim of this substudy was to evaluate local arterial responses through the use of serial quantitative intravascular ultrasound (IVUS) analyses in the TAXUS II trial. METHODS AND RESULTS TAXUS II was a randomized, double-blind study with ...
متن کاملComparison of bare metal stent and paclitaxel-eluting stent using a novel rat aorta stent model
The purpose of our study was to create a novel rat aorta stent implantation model. Stainless steel bare metal stents (BMS) or paclitaxel-eluting stents (PES) were implanted in male Sprague-Dawley rats (BW 400 ± 20 g). Two and four weeks after stent implantation, the aorta were collected, fixed with 2% glutaraldehyde, and cut into two segments. One segment was used for scanning electron microsco...
متن کاملThe effect of variable dose and release kinetics on neointimal hyperplasia using a novel paclitaxel-eluting stent platform: the Paclitaxel In-Stent Controlled Elution Study (PISCES).
OBJECTIVES The aim of this study was to evaluate the effect of variable dose and release kinetics of paclitaxel on neointimal hyperplasia. BACKGROUND Conventional paclitaxel-eluting stents use a durable polymer coating as a vehicle for drug delivery. The Conor stent (Conor Medsystems, Menlo Park, California) with intra-strut wells and erodable polymer is specifically designed for drug deliver...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation
دوره 106 10 شماره
صفحات -
تاریخ انتشار 2002