Adaptive Noise Reduction toward Low-dose Computed Tomography

نویسندگان

  • Hongbing Lu
  • Xiang Li
  • Lihong Li
  • Dongqin Chen
  • Yuxiang Xing
  • Jiang Hsieh
  • Zhengrong Liang
چکیده

An efficient noise treatment scheme has been developed to achieve low-dose CT diagnosis based on currently available CT hardware and image reconstruction technologies. The scheme proposed includes two main parts: filtering in sinogram domain and smoothing in image domain. The acquired projection sinograms were first treated by our previously proposed Karhunen-Loeve (K-L) domain penalized weighted least-square (PWLS) filtering, which fully utilizes the prior statistical noise property and three-dimensional (3D) spatial information for an accurate restoration of the low-dose projections. To treat the streak artifacts due to photon starvation, we also incorporated an adaptive filtering into our PWLS framework, which selectively smoothes those channels contributing most to the streak artifacts. After the sinogram filtering, the image was reconstructed by the conventional filtered backprojection (FBP) method. The image is assumed as piecewise regions each has a unique texture. Therefore, an edge-preserving smoothing (EPS) with locally-adaptive parameters to the noise variation was applied for further noise reduction in image domain. Experimental phantom projections acquired by a GE spiral computed tomography (CT) scanner under 10 mAs tube current were used to evaluate the proposed smoothing scheme. The reconstructed imaged demonstrated that the smoothing scheme with appropriate control parameters provides a significant improvement on noise suppression without sacrificing the spatial resolution.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessing the image quality and eye lens dose reduction using bismuth shielding in computed tomography of brain

Background: Epidemiological studies show that computed tomography (CT) is one of the main sources of ionizing radiations. Shielding of radiosensitive organs is one of the dose reduction methods. This study aimed to assess the eye lens dose reduction and image quality resulting from the use of radio-protective bismuth shield in brain CT imaging. Methods: Bismut...

متن کامل

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

Comparisons of Hounsfield Unit Linearity between Images Reconstructed using an Adaptive Iterative Dose Reduction (AIDR) and a Filter Back-Projection (FBP) Techniques

Background: The HU linearity is an essential parameter in a quantitative imaging and the treatment planning systems of radiotherapy. Objective: This study aims to evaluate the linearity of Hounsfield unit (HU) in applying the adaptive iterative dose reduction (AIDR) on CT scanner and its comparison to the filtered back-projection (FBP).Material and Methods: In this experimental phan...

متن کامل

Recent Development of Low-dose X-ray Cone-beam Computed Tomography

Cone-beam computed tomography (CBCT) is an emerging medical imaging modality used for various clinical applications. However, radiation dose to patients is a major limiting factor for its utility in some applications such as daily patient setup and future adaptive therapy in radiotherapy. In this article, we summarize recent development for dose reduction in CBCT. In particular, we discuss seve...

متن کامل

Dose Reduction Methods in Chest Computed Tomography

Introduction: Computed tomography is one of the most powerful tools for investigating thorax disease, because it shows progression of lung disease much clearer than chest radiography. Technical advances in CT scanners have led to some abilities for CT scanners such as coverage of larger volume, lower noise and ability for acquiring image in one respiratory phase. However, this will be accompani...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003