Rapid, effective and user-friendly immunophenotyping of canine lymphoma using a personal flow cytometer

نویسندگان

  • Stratos Papakonstantinou
  • Inese Berzina
  • Amanda Lawlor
  • Emma J O’Neill
  • Peter J O’Brien
چکیده

BACKGROUND Widespread use of flow cytometry for immunophenotyping in clinical veterinary medicine is limited by cost and requirement for considerable laboratory space, staff time, and expertise. The Guava EasyCyte Plus (Guava Technologies, Hayward, CA, US) is the first, personal, bench-top flow cytometer designed to address these limitations. OBJECTIVE The aim of this study was to adapt the immunohistochemical protocol used for immunophenotyping of canine lymphoma to the personal flow cytometer for rapid, effective and user-friendly application to the diagnosis and prognosis of canine lymphoma and to demonstrate its practicality for widespread veterinary application. Performance of the personal flow cytometer for immunophenotyping T and B lymphocytes in blood and lymph nodes from normal dogs and dogs with lymphoproliferative disease, was assessed using only two monoclonal antibodies (against CD3 and CD21), and by comparison with analysis using two conventional flow cytometers. METHODS 26 dogs with lymphoproliferative disease (23 with lymphoma, 3 with lymphocytic leukaemia) were studied along with 15 controls (2 non-lymphoma lymph nodes and 13 non-leukemic bloods. Lymphocytes were immunostained with fluorescent-labeled, monoclonal antibodies against CD3 and CD21. To assess the effectiveness of the personal flow cytometer in discrimination between T and B cell immunophenotypes, T and B cell counts for half the samples (14 blood and 11 lymph node) were also determined using the same method and conventional flow cytometers (FACSCalibur, Cyan Dako). To assess the effectiveness of the personal flow cytometer in discriminating between leukocyte types, lymphocyte differential counts were determined for 21 blood samples and compared with those from automated hematology analyzers (CELL-DYN 3500, n=11 and ADVIA 2120, n=10). Quality and sub-cellular distribution of immunostaining was assessed using fluorescence microscopy. RESULTS The protocol for immunophenotyping took 2 to 3 hours to complete from the point of receipt of sample to reporting of immunophenotype. The personal flow cytometer differential lymphocyte counts correlated highly (n=20; r=0.97, p<0.0001) with those of automated haematology analyzers. The personal flow cytometer counts consistently, but mildly, underestimated the percentages of lymphocytes in the samples (mean bias of -5.3%.). The personal flow cytometer immunophenotype counts were indistinguishable from those of conventional flow cytometers for both peripheral blood samples (n=13; r=0.95; p<0.0001; bias of -1.1%) and lymph node aspirates (n=11,r=0.98; p<0.001; bias of 1%). All but one leukemic and one lymphomatous lymph node sample, out of 26 samples of dogs with lymphoproliferative disease analyzed, could be immunophenotyped as either B or T cells. CONCLUSIONS We conclude that use of only 2 monoclonal antibodies is sufficient for immunophenotyping most cases of canine lymphoma by flow cytometry and enables rapid immunophenotyping. The personal flow cytometer may be as effectively used for immunophenotyping canine lymphoma as conventional flow cytometers. However, the personal flow cytometer is more accessible and user-friendly, and requires lower sample volumes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Large B-cell lymphoma in a dog: A cyto-histopathological evaluation and Immunophenotyping according to WHO classification for canine lymphomas

In the present study, we described cyto-histopathological features and immunophenotyping of the large B-cell lymphoma in an 8-year-old mixed breed dog with applying the World Health Organization (WHO) system of classification of canine lymphomas. In fine-needle aspiration (FNA), lymph nodes were involved by neoplastic cells of intermediate to large size with deep blue cytoplasm; consist of cent...

متن کامل

A relational database for diagnosis of hematopoietic neoplasms using immunophenotyping by flow cytometry.

A relational database was developed to facilitate the diagnosis of hematopoietic neoplasms using results of immunophenotyping by flow cytometry. This database runs on personal computers and uses backward-chaining search to arrive at conclusions. Results of immunologic marker studies are processed by the database to obtain a set of differential diagnoses. The current version of this database inc...

متن کامل

Use of fine needle aspirates and flow cytometry for the diagnosis, classification, and immunophenotyping of canine lymphomas.

Fifty canine lymphomas were classified cytomorphologically using the updated Kiel classification scheme. Aspirates of lymph nodes from dogs with lymphoma were stained using 5 canine-specific antibodies and 3 human-specific antibodies that cross-react with canine lymphocytes. The antibody-stained aspirates were analyzed by flow cytometry. A total of 32 (64%) of the 50 lymphomas were characterize...

متن کامل

Canine T‐Zone Lymphoma: Unique Immunophenotypic Features, Outcome, and Population Characteristics

BACKGROUND Canine T-cell lymphoma (TCL) is clinically and histologically heterogeneous with some forms, such as T-zone lymphoma (TZL), having an indolent course. Immunophenotyping is an important tool in the classification of TCL in people, and can be equally useful in dogs. HYPOTHESIS/OBJECTIVES We hypothesized that loss of expression of the CD45 antigen is a specific diagnostic feature of T...

متن کامل

External quality assessment in clinical cell analysis by flow cytometry. Why is it so important?

Participation in external quality assessment is an integral part of laboratory work and mandatory when the results have a clinical application, which is one of the requirements of standard 15189 for accreditation of medical laboratories. Institute of Clinical Chemistry, the first laboratory accredited for clinical cell analysis by flow cytometry in Croatia, participated in UKNEQAS for Leukocyte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 66  شماره 

صفحات  -

تاریخ انتشار 2013