In-vivo validation of a new non-invasive continuous ventricular stroke volume monitoring system in an animal model

نویسندگان

  • Maurits K Konings
  • Paul F Grundeman
  • Henk G Goovaerts
  • Maarten R Roosendaal
  • Imo E Hoefer
  • Pieter A Doevendans
  • Frank E Rademakers
  • Wolfgang F Buhre
چکیده

INTRODUCTION Recently, a non-invasive, continuous ventricular stroke volume monitoring system using skin electrodes has been developed. In contrast to impedance-based methods, the new technique (ventricular field recognition) enables measurement of changes in ventricular volume. A prototype using this new method was built (the hemologic cardiac profiler, HCP) and validated against a reference method in a pig model during variations in cardiac output. METHODS In six Dalland pigs, cardiac output was simultaneously measured with the HCP (CO-HCP), and an invasive ultrasonic flow-probe around the ascending aorta (CO-FP). Variations in CO were achieved by change in ventricular loading conditions, cardiac pacing, and dobutamine administration. Data were analysed according to Bland-Altman analysis and Pearson's correlation. RESULTS Pearson's correlation between the CO-HCP and the CO-FP was r = 0.978. Bland-Altman analysis showed a bias of - 0.114 L/minute, and a variability of the bias (2 standard deviations, 2SD) of 0.55 L/minute. CONCLUSIONS The results of the present study demonstrate that CO-HCP is comparable to CO-FP in an animal model of cardiac output measurements during a wide variation of CO. Therefore, the HCP has the potential to become a clinical applicable cardiac output monitor.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis

Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...

متن کامل

Standardization and Validation of Non-invasive Monitoring of End Tidal Carbon Dioxide in Neonates via Nasal Cannula: An Observational Study

Background: Carbon dioxide (CO2) is a by-product of cellular metabolism, which could be considered as a reflection of metabolism, circulation, and ventilation. Arterial blood gas analysis (ABG) is the gold standard of monitoring for CO2. However, is an expensive method leading to blood loss and iatrogenic anemia. In addition, each sample is only a...

متن کامل

A new electric method for non-invasive continuous monitoring of stroke volume and ventricular volume-time curves

BACKGROUND In this paper a new non-invasive, operator-free, continuous ventricular stroke volume monitoring device (Hemodynamic Cardiac Profiler, HCP) is presented, that measures the average stroke volume (SV) for each period of 20 seconds, as well as ventricular volume-time curves for each cardiac cycle, using a new electric method (Ventricular Field Recognition) with six independent electrode...

متن کامل

قلب نگاری امپدانسی روشی برای پایش غیرتهاجمی حجم ضربه ای: یک مطالعه ی مقدماتی

 Abstract Background: Impedance cardiography (ICG) is a simple and inexpensive technique for non-invasive and continues measurement of stroke volume. Due to non-invasive nature, ICG is becoming increasingly used in research and clinical applications. With regard to lack of domestic impedance cardiograph and limited similar imported products in the country, an inexpensive and portable protot...

متن کامل

A Model of the Respiratory System in the Newborn Infant

A dynamic mathematical model is presented which successfully simulates the respiratory control system of the newborn infant in different physiological conditions. The primary objective in constructing this model has been to provide a simulation aid in the investigation of maturation of the respiratory system, and the respiratory disorders during the newborn period, without the need for invasive...

متن کامل