Three-dimensional optical coherence tomography of the embryonic murine cardiovascular system.

نویسندگان

  • Wei Luo
  • Daniel L Marks
  • Tyler S Ralston
  • Stephen A Boppart
چکیده

Optical coherence tomography (OCT) is an emerging high-resolution real-time biomedical imaging technology that has potential as a novel investigational tool in developmental biology and functional genomics. In this study, murine embryos and embryonic hearts are visualized with an OCT system capable of 2-microm axial and 15-microm lateral resolution and with real-time acquisition rates. We present, to our knowledge, the first sets of high-resolution 2- and 3-D OCT images that reveal the internal structures of the mammalian (murine) embryo (E10.5) and embryonic (E14.5 and E17.5) cardiovascular system. Strong correlations are observed between OCT images and corresponding hematoxylin- and eosin-stained histological sections. Real-time in vivo embryonic (E10.5) heart activity is captured by spectral-domain optical coherence tomography, processed, and displayed at a continuous rate of five frames per second. With the ability to obtain not only high-resolution anatomical data but also functional information during cardiovascular development, the OCT technology has the potential to visualize and quantify changes in murine development and in congenital and induced heart disease, as well as enable a wide range of basic in vitro and in vivo research studies in functional genomics.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of an Advanced Optical Coherence Tomography System for Radiation Dosimetry

Introduction: According to the literature, optical coherence tomography (OCT) can be used measure radiation absorbed dose. This study was carried out to design a computed tomography system for the calculation of absorbed dose and optimization of dose delivery in radiotherapy using gel dosimeters. Material and Methods: An advanced charge-coupled device based OCT system was developed in laborator...

متن کامل

Three-dimensional correction of conduction velocity in the embryonic heart using integrated optical mapping and optical coherence tomography.

Optical mapping (OM) of cardiac electrical activity conventionally collects information from a three-dimensional (3-D) surface as a two-dimensional (2-D) projection map. When applied to measurements of the embryonic heart, this method ignores the substantial and complex curvature of the heart surface, resulting in significant errors when calculating conduction velocity, an important electrophys...

متن کامل

Images in Cardiovascular Medicine Non-Destructive, High-Resolution 3-Dimensional Visualization of a Cardiac Defect in the Chick Embryo Resembling Complex Heart Defect in Humans Using Micro-Computed Tomography Double Outlet Right Ventricle With Left Juxtaposition of Atrial Appendages

Nondestructive, high-resolution 3-dimensional (3D) imaging of the embryonic heart remains a challenge in cardiovascular development research. In the past, several imaging techniques (eg, magnetic resonance microscopy, optical coherence tomography) were tested for their suitability to visualize the 3D morphology of embryonic hearts. Most of these imaging tools have their drawbacks with respect t...

متن کامل

Three-Dimensional (3D) Visualisation of the Cardiovascular System of Mouse Embryos and Fetus

The mouse is the most appropriate biomedical model organism for researching the mechanistic function of genetic factors in normal embryogenesis and in the genesis of cardiovascular malformations. Three-dimensional (3D) visualisation of the developing organs of wild type and genetically modified mouse embryos is essential for such research. This paper aims at discussing imaging methods that perm...

متن کامل

Clinical Applications of Optical Coherence Tomography in Ophthalmology

Assessment of the peripapillary nerve fiber layer and macular thickness can be determined in ophthalmology using optical coherence tomography (OCT). Decreased nerve fiber layer thickness and macular ganglion cell thickness in optic nerve ischemia have been correlated with visual field loss. OCT allows deep optic nerve head evaluation which helps understand pathophysiology of diseases.  Furtherm...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of biomedical optics

دوره 11 2  شماره 

صفحات  -

تاریخ انتشار 2006