The quasi-static response of compliant prosthetic sockets for transtibial amputees using finite element methods.
نویسندگان
چکیده
The finite element method (FEM) is a very powerful tool for analyzing the behavior of structures, especially when the geometry and mechanics are too complex to be modeled with analytical methods. This study focuses on the analysis of patellar tendon bearing prosthetic sockets with integrated compliant features designed to relieve contact pressure between the residual limb and socket. We developed a FEM model composed of a socket, liner and residual limb and analyzed it under quasi-static loading conditions derived from experimentally measured ground reaction forces. The geometry of the residual limb, liner and socket were acquired from computed tomography (CT) data of a transtibial amputee. Three different compliant designs were analyzed using FEM to assess the structural integrity of the sockets and their ability to relieve local pressure at the fibula head during normal walking. The compliant features consisted of thin-wall sections and two variations of spiral slots integrated within the socket wall. One version of the spiral slots produced the largest pressure relief, with an average reduction in local interface pressure during single-leg stance (20-80% of the stance phase) from 172 to 66.4 kPa or 65.8% compared to a baseline socket with no compliant features. These results suggest that the integration of local compliant features is an effective method to reduce local contact pressure and improve the functional performance of prosthetic sockets.
منابع مشابه
Clinical Evaluation of Prosthetic Sockets Manufactured By Selective Laser Sintering
A pilot study was undertaken to evaluate the clinical acceptance of prosthetic limb sockets manufactured using solid freeform fabrication (SFF). The fabrication of sockets for amputees is a natural application for SFF. The socket is the part of the prosthetic limb that fits onto the amputee’s residual limb. Each socket is custom manufactured for each individual amputee. Four amputees were succe...
متن کاملDesign and analysis of orthogonally compliant features for local contact pressure relief in transtibial prostheses.
A very attractive advantage of manufacturing prosthetic sockets using solid freeform fabrication is the freedom to introduce design solutions that would be difficult to implement using traditional manufacturing techniques. Such is the case with compliant features embedded in amputee prosthetic sockets to relieve contact pressure at the residual limb-socket interface. The purpose of this study w...
متن کاملA comparison between the dimensions of positive transtibial residual limb molds prepared by air pressure casting and weight-bearing casting methods
Background: Creating a socket with proper fit is an important factor to ensure the comfort and control of prosthetic devices. Several techniques are commonly used to cast transtibial stumps but their effect on stump shape deformation is not well understood. This study compares the dimensions, circumferences and volumes of the positive casts and also the socket comfort between two casting method...
متن کاملTechniques for Interface Stress Measurements within Prosthetic Sockets of Transtibial Amputees: A Review of the Past 50 Years of Research
The distribution of interface stresses between the residual limb and prosthetic socket of a transtibial amputee has been considered as a direct indicator of the socket quality fit and comfort. Therefore, researchers have been very interested in quantifying these interface stresses in order to evaluate the extent of any potential damage caused by the socket to the residual limb tissues. During t...
متن کاملAdvanced Prototyping of Variable Impedance Prosthetic Sockets for Trans-tibial Amputees: Polyjet Matrix 3D Printing of Comfortable Prosthetic Sockets Using Digital Anatomical Data
This work, supported by the Media Lab Consortium, evaluates the design of a Variable Impedance Prosthetic (VIPr) socket for a transtibial amputee using computer-aided design and manufacturing (CAD/CAM). Compliant features are seamlessly integrated into a 3D printed socket to achieve lower interface peak pressures over bony protuberances by using anthropomorphic data acquired through surface sca...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Medical engineering & physics
دوره 28 2 شماره
صفحات -
تاریخ انتشار 2006