The preanalytical and analytical factors responsible for false-positive cardiac troponins
نویسندگان
چکیده
منابع مشابه
The Effect of Preanalytical, Analytical, and Postanalytical Variables on D-dimer Measurement
D-dimer is a soluble fibrin degradation product deriving from the plasmin-mediated degradation of cross-linked fibrin. D-dimer can hence be considered a biomarker of activation of coagulation and fibrinolysis, and it is routinely used for ruling out venous thromboembolism (VTE). D-dimer is increasingly used to assess the risk of VTE recurrence and to help define the uoptimal duration of anticoa...
متن کاملQuality Assurance in the Preanalytical Phase
The preanalytical phase includes a set of processes that are difficult to define because they take place in different places and at different times. Classically, the preanalytical phase included all processes from the time a laboratory request is made by a physician until the sample is ready for testing. While this definition is very informative, errors that occur at this stage often become app...
متن کاملPositive and negative false estimates of serum creatinine
Prabhat K Nigam*, Abhilash Chandra2 1Department of Cardiology, King George’s Medical University, UP, Lucknow 226004, India Department of Nephrology, Dr. Ram Manohar Lohia Institute of Medical Sciences, Gomti Nagar, Lucknow 226010, UP, India *Author for correspondence: Tel: +919235775577 E-mail: [email protected] Submitted: June 21, 2017 Accepted: July 12, 2017 Published online: July 19, 2017 A...
متن کاملThe Evaluation of Error Types and Turnaround Time of Preanalytical Phase in Biochemistry and Hematology Laboratories
Background& Objective: Each laboratory should determine the type of errors and turnaround time (TAT), especially in the preanalytical phase to report quality and timeliness of the test results. The current study aimed at investigating the common causes of preanalytical errors in biochemistry and hematology laboratories and evaluating the preanalytical ...
متن کاملEffects of pre-analytical processes on blood samples used in metabolomics studies
Every day, analytical and bio-analytical chemists make sustained efforts to improve the sensitivity, specificity, robustness, and reproducibility of their methods. Especially in targeted and non-targeted profiling approaches, including metabolomics analysis, these objectives are not easy to achieve; however, robust and reproducible measurements and low coefficients of variation (CV) are crucial...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 15 شماره
صفحات -
تاریخ انتشار 2015