Respiratory gating of anatomical optical coherence tomography images of the human airway.
نویسندگان
چکیده
Anatomical optical coherence tomography (aOCT) is a long-range endoscopic imaging modality capable of quantifying size and shape of the human airway. A challenge to its in vivo application is motion artifact due to respiratory-related movement of the airway walls. This paper represents the first demonstration of respiratory gating of aOCT airway data, and introduces a novel error measure to guide appropriate parameter selection. Results indicate that at least four gates per respiratory cycle should be used, with only minor improvements as the number of gates is further increased. It is shown that respiratory gating can substantially improve the quality of aOCT images and reveal events and features that are otherwise obscured by blurring.
منابع مشابه
Respiratory Gating of Endoscopic OCT Images of the Upper Airway
Anatomical optical coherence tomography (aOCT) is an endoscopic imaging modality that can be used to quantify size and shape of the upper airway. We report the application of respiratory gating to aOCT images. Our results show that respiratory gating can reduce motion artefact in upper airway images. Using an error metric based on distance to the dominant reflection in each A-scan, we found not...
متن کاملExperimental Visualization of Labyrinthine Structure with Optical Coherence Tomography
Introduction:Visualization of inner ear structures is a valuable strategy for researchers and clinicians working on hearing pathologies. Optical coherence tomography (OCT) is a high-resolution imaging technology which may be used for the visualization of tissues. In this experimental study we aimed to evaluate inner ear anatomy in well-prepared human labyrinthine bones.Materials and Methods:Thr...
متن کاملSpeckle Noise Reduction for the Enhancement of Retinal Layers in Optical Coherence Tomography Images
Introduction One of the most important pre-processing steps in optical coherence tomography (OCT) is reducing speckle noise, resulting from multiple scattering of tissues, which degrades the quality of OCT images. Materials and Methods The present study focused on speckle noise reduction and edge detection techniques. Statistical filters with different masks and noise variances were applied on ...
متن کاملTwo-dimensional and 3-dimensional optical coherence tomographic imaging of the airway, lung, and pleura.
BACKGROUND Methods for obtaining real-time in vivo histologic resolution by means of noninvasive endoscopic optical imaging would be a major advance for thoracic surgical diagnostics and treatment. Optical coherence tomography is a rapidly evolving technology based on near-infrared interferometry that might provide these capabilities. The purpose of this study is to investigate the feasibility ...
متن کاملMeasuring airway dimensions during bronchoscopy using anatomical optical coherence tomography.
Airway dimensions are difficult to quantify bronchoscopically because of optical distortion and a limited ability to gauge depth. Anatomical optical coherence tomography (aOCT), a novel imaging technique, may overcome these limitations. This study evaluated the accuracy of aOCT against existing techniques in phantom, excised pig and in vivo human airways. Three comparative studies were performe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Optics express
دوره 17 8 شماره
صفحات -
تاریخ انتشار 2009