Comparison of image reconstruction algorithms in myocardial perfusion scintigraphy.

نویسندگان

  • J Bai
  • J Hashimoto
  • T Suzuki
  • T Nakahara
  • A Kubo
  • S Iwanaga
  • H Mitamura
  • S Ogawa
چکیده

The purpose of this study was to compare the clinical utility of two image reconstruction algorithms in myocardial perfusion SPECT (single-photon emission computed tomography): filtered back-projection (FBP) and ordered subset expectation maximization (OSEM). A rest/stress one-day protocol with 99mTc-MIBI or tetrofosmin was performed on 102 consecutive patients who underwent coronary angiography. After SPECT data acquisition, images were reconstructed with FBP and OSEM algorithms. We assessed diagnostic performance (sensitivity, specificity and accuracy) in detecting coronary artery stenosis and evaluated regional tracer uptake with a 4-point scoring system. Although there were no significant differences in diagnostic performance between FBP and OSEM reconstruction, the OSEM method yielded higher uptake in the RCA area than the FBP method by reducing the count-loss artifact due to hepatic uptake of the tracers. In addition, regional uptake in the LCX area was significantly lower in the OSEM image than in the FBP image; this phenomenon was observed mainly in patients with coronary stenosis and/or infarction in the LCX territory. In conclusion, OSEM and FBP offered comparable diagnostic performance in stress myocardial perfusion SPECT. The OSEM method contributed to reduction of the count-loss artifact in inferior and posterior walls and to easy recognition of hypoperfusion in the LCX area.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of simulated patient motion and its effect on myocardial perfusion SPECT using two reconstruction methods (Filtered Backprojection;FBP and Iterative method) [Persian]

Introduction: Motion of the patient during myocardial perfusion SPECT could potentially results in false perfusion defects. The effect of different reconstruction methods on these artifacts is not studied. Clarification of the relation between the extent, severity and duration of motion with the resultant artifacts may be helpful in designing special soft wares for motion correction. This...

متن کامل

Effects of depression on myocardial perfusion scintigraphy [Persian]

  Introduction: The relationship between depression and coronary artery disease is well established; however assessment of this relationship using functional and semi-quantitative imaging (myocardial perfusion scintigraphy) was lacking. The aim of this study was to assess the relationship between the severity of depression and the severity of myocardial perfusion abno...

متن کامل

Performance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT

  Objective: IQSPECT is an advanced high-speed SPECT modality for performing myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQSPECT compared with conventional SPECT interms of performance based on standard clinical protocols. In addition, we examined the concordance between convention...

متن کامل

Myocardial Perfusion SPECT Imaging in Dextrocardia with Situs Inversus: A Case Report

Dextrocardia is a cardiac positional anomaly in which the heart is located in the right hemithorax with its base-to-apex axis directed to the right and caudad. Situs inversus is an autosomal recessive disorder that causes organs in the chest and abdomen to be positioned in a mirror image from their normal position. Dextrocardia may occur in isolation or as part of situs inversus. Similarly, sit...

متن کامل

Evaluation of myocardial perfusion and function after kidney transplantation by Gated SPECT myocardial perfusion scintigraphy

Introduction: The aim of this study was to evaluate the effect of successful kidney transplantation (KT) on myocardial perfusion and left ventricular function by both qualitative (visual) interpretation and semiquantitative parameters, using myocardial perfusion scintigraphy with gated-single photon emission computed tomography (gated-SPECT) in patients suffering from end-stage renal disease. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of nuclear medicine

دوره 15 1  شماره 

صفحات  -

تاریخ انتشار 2001