Relation between Tc-99m sestamibi uptake and biological factors in hyperparathyroidism.

نویسندگان

  • Tevfik Fikret Cermik
  • Fulya Oz Puyan
  • Atakan Sezer
  • Mehmet Fatih Firat
  • Sakir Berkarda
چکیده

PURPOSE The aim of this study was to evaluate the relation between uptake ratios of Tc-99m sestamibi (MIBI) and tumor volume, serum biochemical values (i-PTH, Ca, P) and oxyphil cell content. MATERIALS AND METHODS The study population consisted of 19 patients (2 M, 17 F; mean +/- SD: 47 +/- 12 y). Anterior planar images of the neck and chest were acquired early (15 min) and triple late phase (1, 2 and 3-4 h) after intravenous injections of 740 MBq MIBI. Each of the surgical materials was reviewed retrospectively. The percentage of cell type (chief, oxyphil and clear cells) in the tumors was calculated by light microscopy. RESULTS The uptake ratio obtained from L1 (1 hour) phase was found to be higher than the uptake ratio obtained from early phase, and the difference was statistically significant (1.57 +/- 0.34 and 1.43 +/- 0.29, p = 0.004, respectively). There was no significant correlation between uptake ratios that were obtained from 4 different imaging phases and lesion volumes, i-PTH levels and calcium levels (p > 0.05). However, there was a significant adverse correlation between L2 and L3 uptake ratios and serum phosphorus values (r = -0.44, p = 0.04 and r = -0.46, p = 0.04, respectively). Additionally, no significant correlation between MIBI uptake ratios of each imaging phase and the laboratory data, volume of lesion or oxyphil percentage volume was found after the multiple regression analysis (E: p = 0.46, r = 0.49; L1: p = 0.24, r = 0.58; L2: p = 0.27, r = 0.57; L3: p = 0.32, r = 0.55, respectively. There was no correlation between gland oxyphil percentage volume and MIBI uptake ratios (p > 0.05). CONCLUSION The results of our study show that the optimal imaging times after intravenous injection of MIBI are 15 minutes and 1 hour because of the shorter examination time without loss of diagnostic ability. In the present study, there was no significant correlation between MIBI uptake ratios and increased gland volume, or serum Ca and i-PTH levels. Besides, we think that oxyphil cell content may not have a main effect on MIBI uptake and retention. The fact of an adverse relation between phosphorus and MIBI retention in our study suggests that phosphorus level should be considered prior to MIBI imaging.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Minimally invasive radio-guided surgery for hyperparathyroidism: an experience with Tc-99m Sestamibi

  Introduction: Radio-guided parathyroid surgery along with other minimally invasive surgeries constitutes the main surgical treatment procedures for different kinds of hyperparathyroidism.  In this article we have reported our experience of radio-guided parathyroid surgery using Tc-99m sestamibi. Methods: Ten patients with hyperparathyroidism included in our study. ...

متن کامل

Thymoma and parathyroid adenoma: false-positive imaging and intriguing laboratory test results.

IMPORTANCE Parathyroid hormone (PTH)-secreting thymomas are an exceedingly rare entity. A PTH-secreting thymoma was discovered in the workup of a patient with primary hyperparathyroidism. A concomitant parathyroid adenoma was removed from the same patient. We present the intriguing clinical course and review the literature on this rare entity. In addition, we discuss the use of scanning with te...

متن کامل

Differences in accuracy of 99mTc-sestamibi scanning between severe and mild forms of primary hyperparathyroidism.

UNLABELLED Preoperative localization of the parathyroids using (99m)Tc-sestamibi scanning has not yet been established as a routine diagnostic procedure for primary hyperparathyroidism. Several studies have demonstrated a variable degree of accuracy (70%-98%) in asymptomatic patients. METHODS We evaluated the accuracy of this technique in 64 patients who underwent scanning between January 200...

متن کامل

99mTechnetium Sestamibi-123Iodine Scintigraphy Is More Accurate Than 99mTechnetium Sestamibi Alone before Surgery for Primary Hyperparathyroidism

Objectives. Studies comparing outcome of single-(99m)Tc-methoxyisobutylisonitrile ((99m)Tc-sestamibi) and dual-tracer (99m)Tc-sestamibi scintigraphy in combination with (123)I before primary surgery of primary hyperparathyroidism (PHPT) are scarce. Methods. We compared (99m)Tc-sestamibi/(123)I and (99m)Tc-sestamibi in a single-centre retrospective series of 269 PHPT patients. The results were r...

متن کامل

Multiple endocrine neoplasia type 1 with anterior mediastinal parathyroid adenoma: successful localization using Tc-99m sestamibi SPECT/CT

The most common manifestation of multiple endocrine neoplasia type 1 (MEN1) is hyperparathyroidism. Treatment of hyperparathyroidism in MEN patients is surgical removal of the parathyroid glands, however ectopic parathyroid gland is challenging for treatment. A 51-year-old female, the eldest of 3 MEN1 sisters, had hyperparathyroidism with ectopic parathyroid adenoma in the mediastinal para-aort...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Annals of nuclear medicine

دوره 19 5  شماره 

صفحات  -

تاریخ انتشار 2005