Association between myocardial substrate, implantable cardioverter defibrillator shocks and mortality in MADIT-CRT.

نویسندگان

  • Nitesh Sood
  • Anne-Christine H Ruwald
  • Scott Solomon
  • James P Daubert
  • Scott McNitt
  • Bronislava Polonsky
  • Christian Jons
  • Christopher A Clyne
  • Wojciech Zareba
  • Arthur J Moss
چکیده

OBJECTIVE The aim of the present study was to assess a possible association between myocardial substrate, implantable cardioverter defibrillator (ICD) shocks, and subsequent mortality. METHODS Within the multicentre automatic defibrillator implantation trial-cardiac resynchronization therapy (MADIT-CRT) population (n = 1790), we investigated the association between myocardial substrate, ICD shocks and subsequent mortality using multivariate Cox regression analyses and landmark analyses at 1-year follow-up. RESULTS The 4-year cumulative probability of ICD shocks was 13% for appropriate shock and 6% for inappropriate shock. Compared with patients who never received ICD therapy, patients who received appropriate shock had an increased risk of mortality [HR = 2.3 (1.47-3.54), P < 0.001], which remained increased after adjusting for echocardiographic remodelling at 1 year (HR = 2.8, P = 0.001). Appropriate anti-tachycardia pacing (ATP) only was not associated with increased mortality (P = 0.42). We were not able to show an association between inappropriate shocks (P = 0.53), or inappropriate ATP (P = 0.10) and increased mortality. Advanced myocardial structural disease, i.e. higher baseline echocardiographic volumes and lack of remodelling at 1 year, was present in patients who received appropriate shocks but not in patients who received inappropriate shocks or no shocks. CONCLUSION In the MADIT-CRT study, receiving appropriate ICD shocks was associated with an increased risk of subsequent mortality. This association was not evident for appropriate ATP only. These findings, along with advanced cardiac structural disease in the patients who received appropriate shocks, suggest that the compromised myocardium is a contributing factor to the increased mortality associated with appropriate ICD shock therapy. Clinical trials.gov identifier: NCT00180271.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inappropriate implantable cardioverter-defibrillator shocks in MADIT II: frequency, mechanisms, predictors, and survival impact.

OBJECTIVES This study sought to identify the incidence and outcome related to inappropriate implantable cardioverter-defibrillator (ICD) shocks, that is, those for nonventricular arrhythmias. BACKGROUND The MADIT (Multicenter Automatic Defibrillator Implantation Trial) II showed that prophylactic ICD implantation improves survival in post-myocardial infarction patients with reduced ejection f...

متن کامل

Cardiac resynchronization therapy reduces left atrial volume and the risk of atrial tachyarrhythmias in MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial with Cardiac Resynchronization Therapy).

OBJECTIVES We hypothesized that reductions in left atrial volume (LAV) with a cardiac resynchronization therapy-defibrillator (CRT-D) would translate into a subsequent reduction in the risk of atrial tachyarrhythmias (AT). BACKGROUND There is limited information regarding the effect of CRT-D on the risk of AT. METHODS Percent reduction in LAV at 1 year following CRT-D implantation (pre-spec...

متن کامل

Mortality reduction in relation to implantable cardioverter defibrillator programming in the Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy (MADIT-RIT).

BACKGROUND The benefit of novel implantable cardioverter defibrillator (ICD) programming in reducing inappropriate ICD therapy and mortality was demonstrated in Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy (MADIT-RIT). However, the cause of mortality reduction remains incompletely evaluated. We aimed to identify factors associated with mortality, with focu...

متن کامل

Long-Term Survival of Multicenter Automatic Defibrillator Implantation Trial (MADIT) II-Eligible Patients in Taiwan.

BACKGROUND he Multicenter Automatic Defibrillator Implantation Trial (MADIT) II showed that use of a prophylactic implantable cardioverter defibrillator (ICD) improved the survival of patients with poor left ventricular ejection fraction after myocardial infarction. The major concerns about primary ICD prevention in Asian countries are the long-term survival and the incidence of sudden cardiac ...

متن کامل

PR interval identifies clinical response in patients with non-left bundle branch block: a Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy substudy.

BACKGROUND In Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy (MADIT-CRT), patients with non-left bundle branch block (LBBB; including right bundle branch block, intraventricular conduction delay) did not have clinical benefit from cardiac resynchronization therapy with defibrillator (CRT-D). We hypothesized that baseline PR interval modulates clinical r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • European heart journal

دوره 35 2  شماره 

صفحات  -

تاریخ انتشار 2014