Cardiac pacemakers, ICDs, and loop recorder: evaluation of translational attraction using conventional ("long-bore") and "short-bore" 1.5- and 3.0-Tesla MR systems.
نویسندگان
چکیده
PURPOSE To evaluate magnet-related translational attraction for cardiac pacemakers, ICDs, and an insertable loop recorder in association with exposure to "long-bore" and "short-bore" 1.5- and 3.0-Tesla MR systems. MATERIALS AND METHODS Fourteen cardiac pacemakers, four ICDs, and one insertable loop recorder were evaluated for translational attraction using deflection angle tests performed at the points of the highest spatial gradients for long-bore and short-bore 1.5- and 3.0-Tesla MR systems according to ASTM guidelines. RESULTS Deflection angles ranged from 9-90 degrees for the long-bore and from 11-90 degrees for the short-bore 1.5-T MR system. Deflection angles ranged from 23-90 degrees for the long-bore and from 34-90 degrees for the short-bore 3.0-T MR system. Three of the cardiovascular implants exhibited deflection angles > or = 45 degrees (i.e., indicating that they are potentially unsafe for patients) on the long-bore and short-bore 1.5-T MR systems. Eight implants exhibited deflection angles > or = 45 degrees on the long-bore 3.0-T MR system, while 14 exhibited deflection angles > or = 45 degrees on the short-bore 3.0-T MR system. In general, deflection angles for these cardiovascular implants were significantly (p < 0.01) higher on 1.5- and 3.0-Tesla short-bore compared to the long-bore MR systems. CONCLUSIONS Several of the cardiovascular implants that underwent evaluation may be problematic for patients undergoing MR procedures using 1.5- and 3.0-T MR systems because of risks associated with magnet-related movements. Obviously, additional MR safety issues must also be considered for these implants.
منابع مشابه
Aneurysm clips: evaluation of magnetic field interactions and translational attraction by use of "long-bore" and "short-bore" 3.0-T MR imaging systems.
BACKGROUND AND PURPOSE The use of 3.0-T MR systems is increasing worldwide. We evaluated magnetic field interactions and translational attraction for 32 aneurysm clips in association with exposure to "long-bore" and "short-bore" 3.0-T MR imaging systems. METHODS Thirty-two different aneurysm clips were evaluated in this investigation. Each aneurysm clip was qualitatively evaluated for magneti...
متن کاملCardiac pacemakers and implantable cardioverter defibrillators: in vitro magnetic resonance imaging evaluation at 1.5-tesla.
RATIONALE AND OBJECTIVES To evaluate the effect of Magnetic Resonance Imaging (MRI) performed at 1.5-Tesla on current generation pacemakers and ICDs to identify safe parameters for MRI examinations. METHODS Pacemakers (Identity ADx XL DR+ 5386 and Identity ADx DR + 5380 generators; 1688T/52-cm atrial and ventricular leads) and ICDs (Atlas + V-243, Epic + V-236, and Epic + HF V-350 generators;...
متن کاملRevisiting Liver Imaging with VIBE
Volume Interpolated Breath-hold Examination (VIBE) [1] offers three-dimensional multiphase image acquisition before and following contrast administration on a breath-hold time scale. The dynamic behavior of liver lesions and structures during the precontrast, arterial, portal venous, early equilibrium and 5-minutedelayed equilibrium phases of enhancement allows more accurate characterization th...
متن کاملUse of a radio frequency shield during 1.5 and 3.0 Tesla magnetic resonance imaging: experimental evaluation
Radiofrequency (RF) shields have been recently developed for the purpose of shielding portions of the patient's body during magnetic resonance imaging (MRI) examinations. We present an experimental evaluation of a commercially available RF shield in the MRI environment. All tests were performed on 1.5 T and 3.0 T clinical MRI scanners. The tests were repeated with and without the RF shield pres...
متن کاملHigh-Field Open versus Short-Bore Magnetic Resonance Imaging of the Spine: A Randomized Controlled Comparison of Image Quality
BACKGROUND The purpose of the present study was to compare the image quality of spinal magnetic resonance (MR) imaging performed on a high-field horizontal open versus a short-bore MR scanner in a randomized controlled study setup. METHODS Altogether, 93 (80% women, mean age 53) consecutive patients underwent spine imaging after random assignement to a 1-T horizontal open MR scanner with a ve...