Cramer-Rao lower bound optimization of an EM-CCD-based scintillation gamma camera.

نویسندگان

  • Marc A N Korevaar
  • Marlies C Goorden
  • Freek J Beekman
چکیده

Scintillation gamma cameras based on low-noise electron multiplication (EM-)CCDs can reach high spatial resolutions. For further improvement of these gamma cameras, more insight is needed into how various parameters that characterize these devices influence their performance. Here, we use the Cramer-Rao lower bound (CRLB) to investigate the sensitivity of the energy and spatial resolution of an EM-CCD-based gamma camera to several parameters. The gamma camera setup consists of a 3 mm thick CsI(Tl) scintillator optically coupled by a fiber optic plate to the E2V CCD97 EM-CCD. For this setup, the position and energy of incoming gamma photons are determined with a maximum-likelihood detection algorithm. To serve as the basis for the CRLB calculations, accurate models for the depth-dependent scintillation light distribution are derived and combined with a previously validated statistical response model for the EM-CCD. The sensitivity of the lower bounds for energy and spatial resolution to the EM gain and the depth-of-interaction (DOI) are calculated and compared to experimentally obtained values. Furthermore, calculations of the influence of the number of detected optical photons and noise sources in the image area on the energy and spatial resolution are presented. Trends predicted by CRLB calculations agree with experiments, although experimental values for spatial and energy resolution are typically a factor of 1.5 above the calculated lower bounds. Calculations and experiments both show that an intermediate EM gain setting results in the best possible spatial or energy resolution and that the spatial resolution of the gamma camera degrades rapidly as a function of the DOI. Furthermore, calculations suggest that a large improvement in gamma camera performance is achieved by an increase in the number of detected photons or a reduction of noise in the image area. A large noise reduction, as is possible with a new generation of EM-CCD electronics, may improve the energy and spatial resolution by a factor of 1.5.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved Cramer-Rao Inequality for Randomly Censored Data

As an application of the improved Cauchy-Schwartz inequality due to Walker (Statist. Probab. Lett. (2017) 122:86-90), we obtain an improved version of the Cramer-Rao inequality for randomly censored data derived by Abdushukurov and Kim (J. Soviet. Math. (1987) pp. 2171-2185). We derive a lower bound of Bhattacharya type for the mean square error of a parametric function based on randomly censor...

متن کامل

Comparative assessment of the accuracy of maximum likelihood and correlated signal enhancement algorithm positioning methods in gamma camera with large square photomultiplier tubes

Introduction: The gamma cameras, based on scintillation crystal followed by an array of photomultiplier tubes (PMTs), play a crucial role in nuclear medicine. The use of square PMTs provides the minimum dead zones in the camera. The camera with square PMTs also reduces the number of PMTs relative to the detection area. Introduction of a positioning algorithm to improve the spat...

متن کامل

An alternative mathematical modeling of the scintillation camera and framework for performance analysis of gamma-ray positioning algorithms

Introduction: Substantive amount of work has been done in modeling and analyzing the scintillation camera system processes including positioning and image formation. The goal of this work is to develop a framework for analyzing performance of nonlinear positioning methods upon construction of a mathematical model of the system. In this study, the photodetector array counts are ...

متن کامل

The influence of electron multiplication and internal X-ray fluorescence on the performance of a scintillator-based gamma camera

When considering the ‘standard’ gamma-camera, one might picture an array of photo-multiplier tubes or a similar array of small-area detectors. This array of imaging detectors would be attached to a corresponding array of scintillator modules (or a solid layer of scintillator) in order to give a high detection efficiency in the energy region of interest, usually 8-140 keV. Over recent years, dev...

متن کامل

Two Approaches on Carrier Frequency Offset Estimation in Mimo Ofdm Systems

We consider the problem of joint carrier frequency offset and channel estimation between transmitter and receiver in a frequency-selective channel MIMO-OFDM system. Recently two high performance estimators based on the expectation-maximization (EM) algorithm have been proposed. The main drawback of the maximum likelihood base algorithms, like EM algorithm, is the high computational complexity. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 58 8  شماره 

صفحات  -

تاریخ انتشار 2013