Should I repeat my 1:2s QC rejection?
نویسندگان
چکیده
BACKGROUND Repeating a QC that is outside 2SD from the mean (1:2s rule) appears to be a common practice. Although this form of repeat sampling is frowned on by many, the comparative power of the approach has not been formally evaluated. METHODS We computed power functions mathematically and by computer simulation for 4 different 1:2s repeat-sampling strategies, as well as the 1:2s rule, the 1:3s rule, and 2 common QC multirules. RESULTS The false-rejection rates for the repeat-sampling strategies were similarly low to those of the 1:3s QC rule. The error detection rates for the repeat-sampling strategies approached those of the 1:2s QC rule for moderate to large out-of-control error conditions. In most cases, the power of the repeat-sampling strategies was superior to the power of the QC multirules we evaluated. The increase in QC utilization rate ranged from 4% to 13% for the repeat-sampling strategies investigated. CONCLUSIONS The repeat-sampling strategies provide an effective tactic to take advantage of the desirable properties of both the 1:2s and 1:3s QC rules. Additionally, the power of the repeat-sampling strategies compares favorably with the power of 2 common QC multirules. These improvements come with a modest increase in the average number of controls tested.
منابع مشابه
Quantum Correlations in Information Theory
The project concerned the study of quantum correlations (QC) in compound systems, i.e. statistical correlations more general than entanglement which are predicted by quantum mechanics but not described in any classical scenario. I aimed to understand the technical and operational properties of the measures of QC, their interplay with entanglement quantifiers and the experimental accessibility. ...
متن کاملFundamental concepts of radiopharmaceuticals quality controls
Quality control (QC) procedures should always be performed following radiopharmaceutical preparation and prior to patient administration. The main aim of QC is to ensure optimal radiopharmaceutical product properties except for some short half-life tracers such as some positron emission tomography (PET) imaging probs. by dispensing a radiopharmaceutical of the highest quality the risk of having...
متن کاملImpact of quality control on radiation doses received by patients undergoing abdomen X-ray examination in ten hospitals
ABSTRACT Background: The X-ray machines used for radiodiagnosis should meet certain quality assurance (QA) programmes . These are necessary to have good quality radiographs at reasonably low exposure to patients. Materials and Methods: Dose reduction methods in abdomen X-ray examination were carried out in 10 hospitals in Tehran. This paper presents the work, which was implemented on 200 ...
متن کاملCysteine-independent activation/inhibition of heme oxygenase-2
Reactive thiols of cysteine (cys) residues in proteins play a key role in transforming chemical reactivity into a biological response. The heme oxygenase-2 (HO-2) isozyme contains two cys residues that have been implicated in binding of heme and also the regulation of its activity. In this paper, we address the question of a role for cys residues for the HO-2 inhibitors or activators designed i...
متن کاملLectures on Quantum Computing and Completely Positive Maps
These are an unedited transcription of lectures I gave at the University of Hous-ton in the Fall of 2011 and should not be circulated widely. This was my first time teaching this material and there are a number of mistakes, etc., that need to be corrected before I show them to a broader audience. The attendees at the IMSC short course on QC in Chennai are welcome to read these, but I ask that t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 58 5 شماره
صفحات -
تاریخ انتشار 2012