Multi-MHz laser-scanning single-cell fluorescence microscopy by spatiotemporally encoded virtual source array.
نویسندگان
چکیده
Apart from the spatial resolution enhancement, scaling of temporal resolution, equivalently the imaging throughput, of fluorescence microscopy is of equal importance in advancing cell biology and clinical diagnostics. Yet, this attribute has mostly been overlooked because of the inherent speed limitation of existing imaging strategies. To address the challenge, we employ an all-optical laser-scanning mechanism, enabled by an array of reconfigurable spatiotemporally-encoded virtual sources, to demonstrate ultrafast fluorescence microscopy at line-scan rate as high as 8 MHz. We show that this technique enables high-throughput single-cell microfluidic fluorescence imaging at 75,000 cells/second and high-speed cellular 2D dynamical imaging at 3,000 frames per second, outperforming the state-of-the-art high-speed cameras and the gold-standard laser scanning strategies. Together with its wide compatibility to the existing imaging modalities, this technology could empower new forms of high-throughput and high-speed biological fluorescence microscopy that was once challenged.
منابع مشابه
Confocal microscopy and multi-photon excitation microscopy of human skin in vivo.
This paper compares tandem scanning reflected light confocal microscopy and multi-photon excitation microscopy for the observation of human skin in vivo. Tandem scanning confocal light microscopy based on a white light source can provide video-rate image acquisition from the skin surface to the epidermal-dermal junction. Multi-photon excitation is induced by a 80 MHz pulse train of femtosecond ...
متن کاملExtended Field Laser Confocal Microscopy (EFLCM): Combining automated Gigapixel image capture with in silico virtual microscopy
BACKGROUND Confocal laser scanning microscopy has revolutionized cell biology. However, the technique has major limitations in speed and sensitivity due to the fact that a single laser beam scans the sample, allowing only a few microseconds signal collection for each pixel. This limitation has been overcome by the introduction of parallel beam illumination techniques in combination with cold CC...
متن کاملImaging of endodontic biofilms by combined microscopy (FISH/cLSM - SEM).
Scanning electron microscopy is a useful imaging approach for the visualization of bacterial biofilms in their natural environments including their medical and dental habitats, because it allows for the exploration of large surfaces with excellent resolution of topographic features. Most biofilms in nature, however, are embedded in a thick layer of extracellular matrix that prevents a clear ide...
متن کاملMultiphoton-excited Fluorescence Imaging and Correlation of Single Quantum Dots Using a Combined Approach of Laser Scanning Microscopy and Fcs
Single quantum dot detection sensitivity can be demonstrated with high spatio-temporal resolution using a combined approach of Fluorescence Correlation Spectroscopy (FCS) , Multi-Channel Scaling (MCS) and Nonlinear (multiphoton-excited) Laser Scanning Microscopy (NLSM) demonstrating the unique opportunities of multi-modality nonlinear laser microscopy in conjunction with quantum dots for probin...
متن کاملFluorescence lifetime imaging by time-correlated single-photon counting.
We present a time-correlated single photon counting (TCPSC) technique that allows time-resolved multi-wavelength imaging in conjunction with a laser scanning microscope and a pulsed excitation source. The technique is based on a four-dimensional histogramming process that records the photon density over the time of the fluorescence decay, the x-y coordinates of the scanning area, and the wavele...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Biomedical optics express
دوره 8 9 شماره
صفحات -
تاریخ انتشار 2017