Interferometric Visibility and Closure Phase of Microlensing Events with Finite Source Size
نویسندگان
چکیده
Interferometers from the ground and space will be able to resolve the two images in a microlensing event. This will at least partially lift the inherent degeneracy between physical parameters in microlensing events. To increase the signal-to-noise ratio, intrinsically bright events with large magnifications will be preferentially selected as targets. These events may be influenced by finite source size effects both photometrically and astrometrically. Using observed finite source size events as examples, we show that the fringe visibility can be affected by ∼ 5-10%, and the closure phase by a few degrees: readily detectable by ground and space interferometers. Such detections will offer unique information about the lens-source trajectory relative to the baseline of the interferometers. Combined with photometric finite source size effects, interferometry offers a way to measure the angular sizes of the source and the Einstein radius accurately. Limb-darkening changes the visibility by a small amount compared with a source with uniform surface brightness, marginally detectable with ground-based instruments. We discuss the implications of our results for the plans to make interferometric observations of future microlensing events.
منابع مشابه
Bringing closure to microlensing mass measurement
Interferometers offer multiple methods for studying microlensing events and determining the properties of the lenses. We investigate the study of microlensing events with optical interferometers, focusing on narrow-angle astrometry, visibility, and closure phase. After introducing the basics of microlensing and interferometry, we derive expressions for the signals in each of these three channel...
متن کاملA Study into the Feasibility of Obtaining Finite Source Sizes from Macho-type Microlensing Light Curves
Recent discussion of the effects of finite source size on high magnification microlensing events due to MACHOs motivates a study into the feasibility of observing such effects and extracting the source radius. Simulated observations are generated by adding Gaussian error to points sampled on theoretical microlensing light curves for a limb darkened, extended source. These simulated data sets ar...
متن کاملFinite Source Effects in Microlensing: a Precise, Easy to Implement, Fast and Numerical Stable Formalism
The goal of this paper is to provide a numerically fast and stable description for the microlensing amplification of an extended source (either uniform or limb-darkened) that holds in any amplification regime. We show that our method of evaluating the amplification can be implemented into a light-curve fitting routine using the Levenberg-Marquardt algorithm. We compare the accuracy and computat...
متن کاملA Brown Dwarf Microlens Candidate in the OGLE-II Database
We describe a unique mass determination for a microlensing event from the second phase of the Optical Gravitational Microlensing Experiment (OGLE-II). The event, sc26 2218, which is very bright (baseline magnitude I = 15.10), appears to exhibit both parallax and finite source effects. The parallax effect allows us to determine the projected Einstein radius on the observer plane (r̃E ≈ 3.8AU), wh...
متن کاملFiber optic interferometry: statistics of visibility and closure phase.
Interferometric observations with three telescopes or more provide two observables: closure phase information and visibility measurements. When single-mode interferometers are used, both observables have to be redefined in the light of the coupling phenomenon between the incoming wave front and the fiber. We introduce the estimator of both the so-called modal visibility and the modal closure ph...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2005