A candidate reference method for determination of total protein in serum. I. Development and validation.
نویسندگان
چکیده
We developed a candidate Reference Method for measuring total serum protein by use of the biuret reaction. The method involves a previously described biuret reagent (Clin. Chem. 21: 1159, 1975) and Standard Reference Material (SRM) 927 bovine albumin (National Bureau of Standards) as the standard. At 25 degrees C, color development for 30 or 60 min provides identical serum protein values. Glucose (up to 10 g/L) and bilirubin (up to 300 mg/L) do not interfere. Hemoglobin, at 3 g/L, increases apparent serum protein by 0.4 g/L. The presence of dextran in serum causes easily detected turbidity, but this interference can be eliminated by centrifuging the reaction mixture. Therapeutic concentrations of ampicillin, carbenicillin, penicillin, oxacillin, nafcillin, chloramphenicol, cephalothin, and methicillin in blood do not interfere, nor do triglycerides up to 10 g/L. Within-run and day-to-day standard deviations of the method are 0.1 and 0.4 g/L, respectively.
منابع مشابه
Development and Validation of HPLC Method for Determination of Crocetin, a constituent of Saffron, in Human Serum Samples
Objective(s):The present study reports the development and validation of a sensitive and rapid extraction method beside high performance liquid chromatographic method for the determination of crocetin in human serum. Materials and Methods:The HPLC method was carried out by using a C18 reversed-phase column and a mobile phase composed of methanol/water/acetic acid (85:14.5:0.5 v/v/v) at the flow...
متن کاملمقایسه روشهای پروتئینزدایی در سنجش نیتریک اکساید سرمی به روش گریس
Background: Nitric oxide (NO) is involved in numerous physiologic and phathophysiologic processes. Recently, further investigators have focused on serum NO determination. In our previous study, we validated a simple, cheap and rapid method for serum NO determination based on the Greiss reaction. Deproteinization is a necessary step for this reaction, thus, the present study was designed to asse...
متن کاملCandidate reference method for determination of total bilirubin in serum: development and validation.
This candidate Reference Method for measuring total bilirubin in serum is based on the Jendrassik-Gróf principle (Clin Chem 29: 297-301, 1983). Standard Reference Material no. 916 bilirubin (National Bureau of Standards) is used as the standard. Bilirubin standard solutions may be prepared either in human serum or in 40 g/L albumin solution (human or bovine), because we found the molar absorpti...
متن کاملDevelopment of near infrared reflectance spectroscopy (NIRS) calibration model for estimation of oil content in a worldwide safflower germplasm collection
The development of NIRS calibration model as a rapid, precise, robust, and cost-effective method to estimate oil content in ground seeds of worldwide safflower germplasm collection grown under different agro-climatic conditions was the key objective of this research project. The oil content was measured by accelerated solvent extraction method in a total of 328 samples collected across 2004 (16...
متن کاملDevelopment and Validation of a Rapid Derivative Spectrophotometric Method for Determination of Tropicamide in Eye Drops
Tropicamide is an antimuscarinic agent used as eye drops for refractive examinations. The aim of this study was to develop a simple and suitable analytical method for determination of tropicamide in eye drops in the presence of excipients. A zero-crossing third and fourth derivative spectrophotometric method was described for determination of tropicamide in eye drops. The measurements wer...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 27 10 شماره
صفحات -
تاریخ انتشار 1981