The AN69 ST haemodialysis membrane under conditions of two different extracorporeal circuit rinse protocols a comparison of thrombogenicity parameters.

نویسندگان

  • Pavlina Richtrova
  • Karel Opatrny
  • Ladislav Vit
  • Frantisek Sefrna
  • Radek Perlik
چکیده

BACKGROUND Thrombogenicity is an important parameter of haemodialysis (HD) membrane biocompatibility. The surface of the polyacrylonitrile AN69 ST membrane is coated with a polyethylenimine. This modification allows heparin adsorption. The binding of heparin to the membrane surface occurs during priming of the extracorporeal circuit (ECC) by rinsing it with saline and heparin. Our aims were to assess and compare the thrombogenicity of the AN69 ST membrane under conditions of two extracorporeal circuit (ECC) rinse protocols-with and without unfractionated heparin (UFH). METHODS In a prospective, crossover and randomized study, we examined 10 patients during HD after ECC preparation with either rinse protocols. Prior to HD and at 15, 60 and 240 min, we determined plasma levels of the thrombin-antithrombin complexes (TAT), platelet factor 4 (PF4), heparin concentration (antiXa) and thrombocyte count. Systemic anticoagulation was performed using UFH. RESULTS During HD after ECC rinse without UFH, there was a significantly earlier and more marked increase in TAT compared with UFH-containing rinse (P <0.05). Using Spearman coefficient, we demonstrated a significant correlation between TAT and antiXa at 60 min (r = -0.534) and 240 min (r = -0.538). A comparison of the TAT/antiXa ratios between rinses at 60 min revealed a significantly higher increase in TAT following UFH-free rinse (P <0.05). There was no difference in PF4 between the rinses. Platelet count did not change significantly during HD using either rinse protocol. CONCLUSION Based on plasma TAT levels, ECC priming with an UFH-containing solution reduces the thrombogenicity of the AN69 ST membrane. There is no significant difference between both types of priming concerning PF4 and thrombocyte count.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The clinical evaluation of low-dose heparin in haemodialysis: a prospective study using the heparin-coated AN69 ST membrane.

BACKGROUND The AN69 ST haemodialysis membrane, a new membrane resulting from coating polyethyleneimine upon the polyacrylonitrile surface, binds heparin. In patients at risk of bleeding, a pilot study has demonstrated the efficient anticoagulant effect of this heparin-coated membrane. Study design. In chronic haemodialyzed patients, we evaluated whether this anticoagulant effect can be validate...

متن کامل

Treatment of severe dialysis reactions with the AN69-ST membrane: biocompatibility does matter

Dialysis reactions with biocompatible membranes are rare, and complement activation has been suggested to be a culprit. We report here a case of an incident haemodialysis patient with asthma disease who experienced severe adverse reactions late into dialysis session, with different synthetic membranes (FX 80, Fresenius; Polyflux 17L, Gambro; FX 10, Fresenius; BLS 512, Bellco-Sorin). After repla...

متن کامل

Intestinal manifestations with a surface-treated AN69 membrane and ACEI during haemodialysis.

Sir, AN69-associated reactions in haemodialysed patients receiving angiotensin-converting enzyme inhibitors (ACEI) are well-documented [1]. The negatively charged AN69 membrane is thought to activate the bradykinin system. Moreover, ACEI reduces bradykinin inactivation. Surface-treated AN69 is considered to be safer in that regard. To our knowledge, only one case of anaphylactoid reaction induc...

متن کامل

A Comparison Between Electrical Circuit and Finite Element Modeling Methods for Performance Analysis of a Three-Phase Induction Motor under Voltage Unbalance

Induction motor is the most popular load in the industry, it is very important to study about the effects of voltage quality on induction motor performance. One of the most important voltage quality problems in power system is voltage unbalance. This paper evaluates and compares two methods including finite element method (FEM) and equivalent electrical circuit simulation for investigation ...

متن کامل

How to perform a haemodialysis using the arterial and venous lines of an extracorporeal life support.

Continuous renal replacement therapy is particularly suited in the setting of acute renal failure, occurring after cardiac surgery, in patients requiring extracorporeal life support (ECLS) or membrane oxygenation. In such patients, temporary catheters are not necessary since the circuit of haemodialysis or haemofiltration may be connected on the ECLS cannulae. We report how to modify a classica...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association

دوره 22 10  شماره 

صفحات  -

تاریخ انتشار 2007