B0 magnetic field homogeneity and shimming for in vivo magnetic resonance spectroscopy.

نویسندگان

  • Christoph Juchem
  • Robin A de Graaf
چکیده

The homogenization of B0 conditions is necessary for every magnetic resonance spectroscopy (MRS) investigation. Its direct consequence is narrow spectral lines, on which reliable separation and quantification of biochemicals, and thus experimentally obtainable metabolic information, fundamentally relies. Besides spectral linewidth, unwanted B0 inhomogeneity also impairs other aspects of the MRS experiment, such as water suppression and editing efficiency, that rely on exact frequency definition. Therefore, experimental B0 homogenization, called B0 shimming, is mandatory for meaningful MRS, and high-level B0 shimming is arguably one of the most important ingredients for successful MRS investigations. In this review, we describe the relevance of B0 homogeneity for in vivo MRS and summarize common concepts and specific solutions for its experimental optimization.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

MRS Shimming: An Important Point Which Should not be Ignored

Introduction: Proton magnetic resonance spectroscopy (MRS) is a well-known device for analyzing the biological fluids metabolically. Obtaining accurate and reliable information via MRS needs a homogeneous magnetic field in order to provide well-defined peaks and uniform water suppression. There are lots of reasons which can disturb the magnetic field homogeneity which can be corrected by a proc...

متن کامل

Shimming and MRS

Adjustment of the static magnetic field homogeneity, commonly known as the B0 shimming or simply shimming, is essential for magnetic resonance spectroscopy because it determines the spectral resolution which is critical for reliable metabolite quantification. Inhomogeneities in the B0 field, resulting primarily from susceptibility differences between air and tissue, are scaled with the B0 field...

متن کامل

Reducing image artefacts in concurrent TMS/fMRI by passive shimming

A significant problem in the concurrent application of transcranial magnetic stimulation (TMS) and functional magnetic resonance imaging (fMRI) is the image artefact caused by the effect of the TMS-coil on the homogeneity of the static magnetic field (B0). The resulting field inhomogeneity can lead to spatial distortions and local signal loss in echo-planar (EP) images. Here we demonstrate that...

متن کامل

Computerized Shimming with the Tuning Algorithm

Introduction The efficiency of automation with large numbers of individual samples and the quality of the acquired spectra depend heavily on the efficiency and quality of adjustments made to the B0 field homogeneity (shimming) after each sample change. The adjustments required depend mainly on sample properties such as bulk magnetic susceptibility of the solvent, volume, and position within the...

متن کامل

Passive Shimming of MRI Static Magnetic Field Using Regularization of Truncated Singular Value Decomposition

PURPOSE To develop a new shimming calculation method, which can calculate iron piece placements rapidly to make the magnetic field homogeneous at intended homogeneity and then to make the shimming working time short. MATERIALS AND METHODS The shimming calculation yields magnetic moment (MM) distribution, which is calculated by the truncated singular value decomposition (SVD) from the measured...

متن کامل