Highly selective DNA-based sensor for lead(II) and mercury(II) ions.

نویسندگان

  • Chi-Wei Liu
  • Chih-Ching Huang
  • Huan-Tsung Chang
چکیده

We have developed a technique for the highly selective and sensitive detection of Pb(2+) and Hg(2+) using a thrombin-binding aptamer (TBA) probe labeled with the donor carboxyfluorescein (FAM) and the quencher 4-([4-(dimethylamino)phenyl]azo)benzoic acid (DABCYL) at its 5' and 3' termini, respectively. The TBA has a random coil structure that changes into a G-quartet structure and a hairpin-like structure upon binding Pb(2+) and Hg(2+) ions, respectively. As a result, the fluorescence decreases through fluorescence resonance energy transfer (FRET) between the fluorophore and quencher. These changes in fluorescence intensity allow the selective detection of Pb(2+) and Hg(2+) ions at concentrations as low as 300 pM and 5.0 nM using this TBA probe in the presence of phytic acid and a random DNA/NaCN mixture, respectively. The linear correlation existed between the fluorescence intensity and the concentration of Pb(2+) and Hg(2+) over the range of 0.5-30 nM (R(2) = 0.98) and 10-200 nM (R(2) = 0.98), respectively. To the best of our knowledge, this is the first example of a single DNA-based sensor that allows the detection of both Hg(2+) and Pb(2+) ions. This simple and cost-effective probe was also applied to separately determine Pb(2+) in soil samples and spiked Hg(2+) in pond samples.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Electrochemical Sensor Based on Novel Ion Imprinted Polymeric Nanoparticles for Selective Detection of Lead Ions

In this study, the novel surface ion-imprinted polymer (IIP) particles were prepared and applied as a electrode modifier in stripping voltammetric detection of lead(II) ion. A carbon paste electrode (CPE) modified with IIP nanoparticles and multi-walled carbon nanotubes (MWCNTs) was used for accumulation of toxic lead ions. Various factors that govern on electrochemical signals including carbon...

متن کامل

New Coated Graphite Potentiometric Sensor for Selective Determination of Copper (II) Ions

A highly selective copper (II) coated graphite sensor was prepared by 1,13-bis(8-quinolyl)- 1,4,7,10,13-pentaoxatridecane (kryptofix 5) as a supramolecule ionophore into plasticized polyvinyl chloride (PVC) membrane. The best response characteristic was observed using the membrane composition of PVC = 30.0 mg, dioctyl sebacate (DOS) = 63.5 mg, palmitic acid (PA) = 3.0 mg and kryptofix 5 = 3.5 m...

متن کامل

Design and Evaluation of a Mercury (II) Optode Based on Immobilization of 5, 6 Di methyl -1- (4 methyl benzyl) -2- para tolyl-1H-benzimidazole (DMBPTBI) on a Triacetylcellulose Membrane and Determination in Various Samples

The characterization of an optical sensor membrane is described for the determination of Hg2+ ions based on the immobilization of 5, 6 Di methyl -1- ( 4 methyl benzyl) -2- para tolyl-1H-benzimidazole (DMBPTBI) on a triacetylcellulose membrane. The membrane responds to mercury ions by changing color reversibly from orange to red in universal buffer solution at pH 2. Under optimum conditions, the...

متن کامل

Construction of a Carbon Paste Electrode Based on Novel Thiolated Ligand Capped Gold Nanoparticles for Determination of Trace Amounts of Mercury(II)

In the present study, a simple electrochemical sensor for trace determination of Hg(II) ions in aqueous solutions was introduced. The proposed sensor was designed by incorporation of the 4-methyl-piperidine-carbodithioate capped gold nanoparticles (GNPs) into the carbon paste electrode (CPE), which provides a remarkably improved sensitivity for stripping voltammetric determination of Hg(II). Di...

متن کامل

Ion-Selective Carbon Paste Electrode Based on 2-Amino-N-benzthioazolyl Benzamide (ABTB) for Determination of Copper (II) by Potentiometric Method

2-Amino-N-benzthioazolyl benzamide (ABTB) was synthesized, characterized and used for thefabrication of a potentiometric sensor for Cu2+ metal ions. The electrode exhibits linear response to Cu(II) over a wide concentration range (4.79×10 -8 – 1.85×10 -1 M) with Nernstian slope of 30 ± 1.5 mVper decade. The electrode can be used in the pH range from 2 to 9. It has a fast response time of about1...

متن کامل

Cu(II) Ion- Selective Membrane Electrode Based on bis(N-salicylidene-3,3'-diamino diphenyl) sulfone

In order to study the Cu(II) ion selective electrode, an optimized membrane was prepared by mixing of 30 mg of PVC powdered, 5 mg of considered ionophore, 60 mg of plasticizer and 5 mg of additive. The sensor showed a near Nernstian response for Cu(II) ions over a concentration range from 1.0×0-6 –1.0×0-2 M with a slope of 28.90.5 mV per concentration decade with a working pH range of 3.5-6.3. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical chemistry

دوره 81 6  شماره 

صفحات  -

تاریخ انتشار 2009