Vessel-specific mapping of cerebral venous oxygenation of small veins

نویسندگان

  • Lisa C. Krishnamurthy
  • Hanzhang Lu
چکیده

Target Audience MR Physicists and Clinicians interested in venous oxygenation quantification, especially effect of artifact on accuracy. Purpose The ability to measure human brain metabolism on a routine basis will have a large impact on the diagnosis and treatment of brain disorders. A key component in quantifying oxygen metabolism is the measurement of venous blood oxygenation (Yv) . Several potential approaches have been proposed to quantify Yv using MRI, including intravascular T2-based methods which rely on a simple and calibratable relationship between blood T2 and oxygenation. Recently we introduced such a T2based method to measure Yv along the major draining vessels of the brain called T2-Relaxation-Under-Phase-Contrast (TRU-PC) MRI. We showed that TRU-PC is a non-invasive, rapid, and reproducible method to measure vessel-specific Yv, but fell short of mapping the Yv of small veins (caliber of 1-2 mm). The ability to generate such a “small-vessel map” of Yv may help in better characterizing variations in venous oxygenation across brain regions, identifying regions at risk of ischemia attack or stroke, and may find immediate applications in clinical conditions that affect specific brain regions. The present study aims to optimize TRU-PC to generate a complete Yv map of the vasculature in the mid-sagittal brain, including small veins. The optimization includes removing an eddy-current induced artifact to improve the Yv quantification, performing multiple scans to sensitize the maps to vessels with different flow velocity and orientation, and merging these scans into a single, comprehensive Yv map. Methods Removing eddy-current induced artifact: The TRU-PC MRI technique applies the Phase Contrast (PC) principle to separate pure blood signal from the surrounding static tissue. The T2 value of pure blood is then determined using non-selective T2-preparation pulses, which minimizes the effect of flow on T2 estimation. PC MRI applies two bipolar gradients in opposite directions in order to cancel out the tissue signal during complex subtraction of the images, resulting in a complex difference (CD) image. However, the application of flow-encoding bipolar gradients can generate eddy-currents that cannot be cancelled out by the application of an opposite bipolar gradient, resulting in an imperfect removal of tissue signal. This tissue signal will superimpose on the vessel signal, resulting in an inaccurate T2quantification. We propose to use a method developed to remove field-imperfections to remove the arbitrary phase generated by eddy-currents. This correction will remove unwanted tissue signal and improve the T2-quantification of blood. We assume that the measured phase difference (Δφ) is a linear combination of the true phase difference (Δθ) and a phase caused by eddy-currents (Δε): Δφ=Δθ+Δε. We reconstruct the Δφ images from the complex data, and calculate a hyper-plane of field inhomogeneity (Δε) from the Δφ images using all eTEs simultaneously for the fitting. By subtracting Δε from Δφ, the true phase difference, Δθ, remains. By using the law of cosines, the CD images are reconstructed using the true phase difference, Δθ. Sensitizing the Yv maps to more vessels: To acquire the complete vasculature in the mid-sagittal brain at 3T (Philips Achieva, 32 Ch. Receive headcoil), four separate TRU-PC scans were employed: one small-vessel scan with flow-encoding in Anterior-Posterior (AP) direction, one small-vessel scan with flow encoding in Foot-Head (FH) direction, and two large-vessel scans, also in AP and FH. The MR protocols for the large-vessel and small-vessel scans are similar, with the only difference being the flow-encoding cut-off velocity (Venc) (Vlarge=15 cm/sec, Vsmall=3 cm/sec for Male, and 5 cm/sec for Female), and recovery time (RT) (RTlarge=475 ms, RTsmall=668 ms). The T2-preparation incorporates hard composite pulses, MLEV16 phase cycled, with τCPMG=10 ms. This results in four sets of complex images with two effective TEs (eTE = 0 and 40 ms). Due to short blood T2*, the TE was set to “shortest” with a conventional gradient echo (FOV = 200x200 mm, acq matrix = 276x83, reconstruction matrix=400x400, 1 slice, slice thickness = 5 mm). The total scan time is ~15 minutes. Merging multiple scans: After the session, the CD images for each eTE were reconstructed individually for each of the four scans as described above. Then the signal intensity from the four scans was thresholded at an SNR of 2.5, and the voxel-wise T2 value was thresholded to be less than 140 ms based on venous blood T2 at 3T. Finally, the signal from all four scans was merged using sum-of-squares method, and the arteries were removed with a vein mask generated from Susceptibility Weighted Imaging (SWI). The T2-map was generated on a voxel-by-voxel basis along the entire vascular path using a mono-exponential model, where the signal from non-zero voxels within a 35x35 voxel block were incorporated in the T2-fitting to reduce error due to noise. The T2 was then converted to Yv using a known calibration plot. Five subjects (3 Female/2 Male, age 21-40) were scanned twice with the entire protocol. We compare the results with and without eddy-current correction. Results and Discussion Figure 1 shows a representative Δφ and CD image for one eTE before and after eddy-current correction for a single TRU-PC scan. Before correction, a non-zero Δφ is present in some of the regions of static tissue that should ideally be zero (red arrow). This non-zero Δφ translates to an aberrant tissue signal in the CD image (yellow arrow). After correction, the Δφ image is closer to the true phase, Δθ (blue arrow), which translates to a better reconstructed CD image (green arrow). Since the small vessel map fuses four separate scans, there will be an accumulation of error during the merging of scans. By correcting for eddy-currents, there was a 30±17% reduction of accumulated error (i.e tissue signal) in the prefrontal region (p=0.001), 33±18% reduction of accumulated error in the parietal region (p=0.008), and 27±19% reduction of accumulated error in the occipital region (p=0.009). Figure 2 shows representative T2 and Yv maps before and after correction. The average T2 value before and after correction was 70.5±7.1 ms and 66.7±5.3 ms, respectively. The corrected T2 is smaller than the uncorrected one for all five subjects (between -2.17 ms and -7.16 ms), which is expected since the tissue T2 at 3T is higher (90-95 ms) than blood T2 (55-85 ms). The amount of correction is dependent on the severity of the artifact being removed, and the voxel’s tissue to blood content. The voxel-wise coefficient of variation (CoV) averaged over the entire vascular path of 2.5±1.5% before correction was not significantly different than the CoV of 2.9±1.8% after correction (p=0.23), showing that the excellent test-retest reliability was not perturbed by the correction. In Figure 3, a representative (corrected) Yv map is super-imposed on its anatomical SWI magnitude image. The named vessels in the image are marked with red letters. Many more un-named vessels (including pial vessels draining into the SSS) are also visible in the map. After correction, we still observe that the vessels draining the deep brain tend to have a higher Yv than the vessels draining the cortex, and that the anterior portion of the SSS has a slightly higher Yv than the posterior portion. Conclusion In summary, we have optimized TRU-PC MRI to obtain a complete map of Yv from the brain’s mid-sagittal draining veins (diameter of 1 mm or greater). This includes the removal of aberrant static tissue signal generated by eddy-currents, which improves the T2-quantification of venous blood signal. We have also sensitized our acquisition to many more vessels, and we have shown that a single complete Yv map can be generated from these scans. This improved vessel-specific Yv map provides a better region-specific measurement of oxygenation and metabolism in the brain. References 1. Xu et al. MRM 62:141 (2009). 2. Lu & Ge. MRM 60:357 (2008). 3. Krishnamurthy, et al. MRM, in press (2013). 4. Bernstein, et al. MRM 32:330 (1994). 5. Langham, et al. MRM 61:626 (2008). 6. Lu, et al. MRM 67:42 (2012). 7. Haacke, et al. MRM 52:612 (2004).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative oxygenation venography from MRI phase.

PURPOSE To demonstrate acquisition and processing methods for quantitative oxygenation venograms that map in vivo oxygen saturation (SvO2 ) along cerebral venous vasculature. METHODS Regularized quantitative susceptibility mapping (QSM) is used to reconstruct susceptibility values and estimate SvO2 in veins. QSM with ℓ1 and ℓ2 regularization are compared in numerical simulations of vessel str...

متن کامل

Quantification of dynamic changes in cerebral venous oxygenation with MR phase imaging at 1.9 T.

A double-echo magnetic resonance (MR) phase imaging method was used to measure the time-dependent changes in regional cerebral venous blood oxygenation during neural stimulation. Our results showed that a finger opposition task induced an absolute increase of blood oxygenation level of deltaY = 0.16+/-0.05 (n = 6), which was measured in the small veins located in the left central sulcus. It was...

متن کامل

Whole-brain mapping of venous vessel size in humans using the hypercapnia-induced BOLD effect

Measuring the morphology of the cerebral microvasculature by vessel-size imaging (VSI) is a promising approach for clinical applications, such as the characterization of tumor angiogenesis and stroke. Despite the great potential of VSI, this method has not yet found widespread use in practice due to the lack of experience in testing it on healthy humans. Since this limitation derives mainly fro...

متن کامل

Loss of venous integrity in cerebral small vessel disease: a 7-T MRI study in cerebral autosomal-dominant arteriopathy with subcortical infarcts and leukoencephalopathy (CADASIL).

BACKGROUND AND PURPOSE Previous pathological studies in humans or in animal models have shown alterations of small arteries and veins within white matter lesions in cerebral small vessel disease. We aimed to evaluate in vivo, the integrity of the cerebral venous network using high-resolution MRI both within and outside white matter hyperintensities in cerebral autosomal-dominant arteriopathy wi...

متن کامل

Mapping cortical columnar structures using fMRI.

Mapping cortical columnar structures is important to understand cortical information processing. To map submillimeter columnar structures noninvasively, we have evaluated various functional magnetic resonance imaging (fMRI) techniques using a well-established feline orientation column model. The conventional positive blood oxygenation level-dependent (BOLD) signal is widespread and diffuse due ...

متن کامل

Hypercapnic normalization of BOLD fMRI: comparison across field strengths and pulse sequences.

The blood oxygenation level-dependent (BOLD) functional magnetic resonance imaging (fMRI) signal response to neural stimulation is influenced by many factors that are unrelated to the stimulus. These factors are physiological, such as the resting venous cerebral blood volume (CBV(v)) and vessel size, as well as experimental, such as pulse sequence and static magnetic field strength (B(0)). Thus...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013