Monoplace hyperbaric chamber use of U.S. Navy Table 6: a 20-year experience.
نویسنده
چکیده
We report a 20-year experience at LDS Hospital, Salt Lake City, UT using the U.S. Navy Treatment Table 6 (TT6) in an oxygen-filled monoplace hyperbaric chamber (1985-2004). Air breathing was provided via a demand regulator fitted with a SCUBA mouthpiece while the patient wore a nose clip. Intubated patients were mechanically ventilated with a Sechrist 500A ventilator, with a modified circuit providing air, when specified. We treated 90 patients: 72 divers (decompression sickness [DCS] = 67, arterial gas embolism [AGE] = 5), 10 hospital-associated AGE, and 8 miscellaneous conditions. They received a total of 118 TT6 (9 TT6 in intubated patients). Ninety-four percent of the TT6 schedules were tolerated and completed. The intolerance rate from two surveyed multiplace chambers was zero and 3% of 100 TT6 schedules each. Failure to complete the TT6 was due to oxygen toxicity (4) and claustrophobia (3). The U.S. Navy TT6 was well tolerated by patients with DCS or AGE treated in monoplace hyperbaric chambers, but tolerance may not be as high as when treated in the multiplace chamber.
منابع مشابه
The monoplace hyperbaric chamber and management of decompression illness.
Three cases of decompression illness are reported. Two patients presented with joint pain and skin signs, while one patient presented with joint pain and neurological signs and symptoms. The patients received emergency recompression therapy in a Hong Kong clinic, using a monoplace hyperbaric chamber. All three patients were treated successfully and no residual signs or symptoms were evident on ...
متن کاملPerformance of infusion pumps during hyperbaric conditions.
BACKGROUND Many hyperbaric facilities use infusion pumps inside the chamber. It is therefore important to ensure that this equipment will perform accurately during hyperbaric conditions. The authors tested the function and accuracy of the Imed 965 and Infutec 520 volumetric infusion pumps, the Easy-pump MZ-257 peristaltic infusion pump, and the Graseby 3100 syringe pump. METHODS The authors c...
متن کاملDecompression tables and dive-outcome data: graphical analysis.
We compare outcomes of experimental air dives with prescriptions for ascent given by various air decompression tables. Among experimental dives compiled in the U.S. Navy Decompression Database, many profiles that resulted in decompression sickness (DCS) have longer total decompression times (TDTs, defined as times spent at decompression stops plus time to travel from depth to the surface) than ...
متن کاملDelayed treatment of decompression sickness with short, no-air-break tables: review of 140 cases.
INTRODUCTION Most cases of decompression sickness (DCS) in the U.S. are treated with hyperbaric oxygen using U.S. Navy Treatment Tables 5 and 6, although detailed analysis shows that those tables were based on limited data. We reviewed the development of these protocols and offer an alternative treatment table more suitable for monoplace chambers that has proven effective in the treatment of DC...
متن کاملTitanium in a hyperbaric oxygen environment may pose a fire risk.
The use of titanium during hyperbaric oxygen therapy may pose a risk of fire. A fresh titanium surface in a high oxygen atmosphere can be a source of ignition. The clinical scenario may be a patient who accidentally breaks his titanium-framed glasses during a hyperbaric oxygen treatment in a monoplace chamber or using an oxygen hood. We recommend some safety precautions to be exercised until co...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Undersea & hyperbaric medicine : journal of the Undersea and Hyperbaric Medical Society, Inc
دوره 33 2 شماره
صفحات -
تاریخ انتشار 2006