The systematic characterization by aqueous column chromatography of solutes which affect protein stability.
نویسندگان
چکیده
We have systematically characterized, by aqueous column chromatography on a size exclusion cross-linked dextran gel (Sephadex G-10), 12 solutes, 11 of which are known to affect protein stability. Six are chaotropes (water structure breakers) and destabilize proteins, while five are polar kosmotropes (polar water structure makers) and stabilize proteins. Analysis of the chromatographic behavior of these neutral (ethylene glycol, urea), positively charged (Tris, guanidine, as the hydrochloride salts) and negatively charged (SO2-4, HPO2-4, F-, Cl-, Br-, Cl3CCO-2, I-, SCN-, as the sodium salts, in order of elution) solutes at pH 7 as a function of sample concentration (up to 0.6 M), supporting electrolyte, and temperature yields four conclusions, based largely on the behavior of the anions. Chaotropes adsorb to the gel according to their position in the Hofmeister series, with the most chaotropic species adsorbing most strongly. ++Chaotropes adsorb to the gel less strongly in the presence of chaotropes (a salting in effect) and more strongly in the presence of polar kosmotropes (a salting out effect). Polar kosmotropes do not adsorb to the gel, and are sieved through the gel according to their position in the Hofmeister series, with the most kosmotropic species having the largest relative hydrodynamic radii. The hydrodynamic radii of polar kosmotropes is increased by chaotropes and decreased by polar kosmotropes. These results suggest that a chaotrope interacts with the first layer of immediately adjacent water molecules somewhat less strongly than would bulk water in its place; a polar kosmotrope, more strongly.
منابع مشابه
Purification and characterization of antiviral protein from silkworm fecal matter
Antiviral proteins (AVP), present in silkworm fecal matter, show activity against nuclear polyhedrosis virus (NPV) in vitro and in vivo. The extract of silkworm fecal matter prepared in phosphate buffer solution of pH 7.5 was subjected to 50% solid ammonium sulfate precipitation to enrich AVP, then which was dialyzed. The dialysate was applied to the column containing silica gel-G, the column e...
متن کاملPartial Purification and Characterization of Anticoagulant Factor from the Snake (Echis carinatus) Venom
Objective(s): Snake venoms contain complex mixture of proteins with biological activities. Some of these proteins affect blood coagulation and platelet function in different ways. Snake venom toxin may serve as a starting material for drug design to combat several pathophysiological problems such as cardiovascular disorders. In the present study, purification of anticoagulation facto...
متن کاملOsmolyte-Induced Folding and Stability of Proteins: Concepts and Characterization
It is well-known that the typical protein’s three-dimensional structure is relatively unstable in harsh conditions. A practical approach to maintain the folded state and thus improve the stability and activity of proteins in unusual circumstances is to directly apply stabilizing substances such as osmolytes to the protein-containing solutions. Osmolytes as natural occurring organic molecules ty...
متن کاملSynthesis, Characterization and Application of a Novel Zirconium Phosphonate Ion-Exchanger for Removal of Ni2+, Cu2+ and Zn2+ from Aqueous Solutions
A new category of hybrid organic-inorganic zirconium phosphonate, Zr[(O3PCH2)2NC6H4CO2H].2H2O was synthesized and the applicability of the prepared sorbent as an ion-exchanger for removal of Ni2+, Cu2+ and Zn2+ from aqueous solutions was evaluated. The characterization of the synthe...
متن کاملSeparation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column
The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of biological chemistry
دوره 261 27 شماره
صفحات -
تاریخ انتشار 1986