CMS ECAL FENIX ASIC design methodology

نویسنده

  • M. Hansen
چکیده

A technique estimated to decrease risk when developing complex digital ASICs is presented. Specification errors as well as discrepancy between the product and the specification are addressed. The CMS ECAL FENIX ASIC development [1] is presented as an example. The ASIC features a fully synthesizable and highly testable implementation of triple-redundancy. The RAM blocks are individually tested by a built in self test, and an error correction code is protecting the data integrity during normal operation. The ASIC has been irradiated during operation together with the complete CMS ECAL front end system, and a preliminary result is presented.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Qualification of the Front End Cards for the CMS ECAL

The Front End (FE) card is a critical component of the new readout architecture for the CMS ECAL. The module hosts the Front End New Intermediate data eXtractor (FENIX) ASIC that contains the DSP for trigger primitive generation and RAM for the digital pipeline and the primary event buffers. The Front end Automatic Tester (FAT) allows fast fault detection to ensure that the manufacturing proces...

متن کامل

Modular approach for an ASIC integration of electrical drive controls

VLSI circuits design allows today to consider new modes of implementation for electrical controls. However, design techniques require an adaptation effort that few designers, too accustomed to the software approach, provide. The authors of this article propose to develop a methodology to guide the electrical designers towards optimal performances of control algorithms implementation. Thus, they...

متن کامل

The CMS electromagnetic calorimeter

From 2007 the new CERN proton proton collider will start collisions that could open new perspectives in the fields of high energy particle physics. The CMS experiment at the LHC is in advanced construction phase. In particular new physics could be discovered thanks to the CMS precise electromagnetic calorimeter (ECAL) made of about 75000 scintillating PbWO 4 crystals. A description of the ECAL ...

متن کامل

The CMS ECAL project – Overview and status report

An overview is given of the Lead Tungstate (PbWO4) electromagnetic crystal calorimeter for the CMS detector at the Large Hadron Collider (LHC) at CERN in Geneva. This includes a description of the engineering design, the development of the calorimeter components, the read-out system and results obtained in particle beams. Presented at IEEE Nuclear Science Symposium, Toronto, Canada, November 19...

متن کامل

Lackey for IBM ASIC products by J . J . Engel

The IBM ASIC design methodology enables a product developer to fully incorporate the high-density, high-performance capabilities of the IBM CMOS technologies in the design of leading-edge products. The methodology allows the full exploitation of technology density, performance, and high testability in an ASIC design environment. The IBM ASIC design methodology builds upon years of experience wi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004