Validity and accuracy of regional bioelectrical impedance devices to determine whole-body fatness.

نویسندگان

  • Henry C Lukaski
  • William A Siders
چکیده

OBJECTIVE Growing emphasis on obesity as a risk factor for chronic diseases and commercial availability of impedance devices for the at-home assessment of body fatness have stimulated the need for a critical evaluation of the validity of these instruments. This study determined the reproducibility and accuracy of two commercial impedance devices that use upper (hand-to-hand) or lower (foot-to-foot) body contact electrode placements in adults with a wide range of body fatness. METHODS Body composition was assessed with dual x-ray absorptiometry in apparently healthy adults (62 women and 48 men) ages 21 to 60 y, with a range in body mass index of 18.6 to 40.5 kg/m2. Variability in body fatness predicted with the regional body impedance devices was determined in 10 adults on 5 consecutive d. A 50-kHz, tetrapolar bioelectrical impedance plethysmograph with surface electrode placements on the upper and lower limbs was used to determine reference regional and whole-body impedance values. RESULTS Variability in body mass (1%) over 5 d was less than body fatness predicted with the upper (2-10%) and lower (3-5%) body devices. Regional and whole-body impedance values were different (P < 0.05) in the women, whereas upper and lower body values were lower (P < 0.05) than whole-body impedance in the men. Dual x-ray absorptiometric determinations of body fatness were similar to predictions based on models derived from physical characteristics (age, stature, body mass, and sex) but significantly different (P < 0.05) from estimates from the impedance devices, which underestimated body fatness. Bias in predictions of body fatness with the regional devices was systematically (P < 0.0001) related to body fatness. CONCLUSION Use of regional impedance devices to assess body fatness is limited by a lack of precision and accuracy.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The validity of predicted body composition in Chinese adults from anthropometry and bioelectrical impedance in comparison with densitometry.

Body composition was measured by densitometry in a group of eighty-one Chinese males and 124 healthy Chinese females, aged 18-67 years. Biceps, triceps, subscapular and suprailiac skinfolds were measured as well as total body bioelectrical impedance at 50 kHz. Mean heights were 1.71 (SD 0.05) and 1.61 (SD 0.06) m, body weights 66.1 (SD 9.1) and 57.2 (SD 9.4) kg and BMI 22.7 (SD 3.0) and 22.0 (S...

متن کامل

Bioelectrical Impedance versus Body Mass Index for Predicting Body Composition Parameters in Sedentary Job Women

Objective: Nowadays the value of bioelectrical impedance analysis (BIA) in the estimation of body adiposity both on a clinical basis in the individual and epidemiologically in large populations is of great interest. The current study determine accuracy of BIA compared with body mass index (BMI) measurement for estimating body composition in a group of normal weight employee women with a sedenta...

متن کامل

Validation of tetrapolar bioelectrical impedance method to assess human body composition.

This study was conducted to validate the relationship between bioelectrical conductance (ht2/R) and densitometrically determined fat-free mass, and to compare the prediction errors of body fatness derived from the tetrapolar impedance method and skinfold thicknesses, relative to hydrodensitometry. One-hundred and fourteen male and female subjects, aged 18-50 yr, with a wide range of fat-free ma...

متن کامل

Comparison of the predicting body fat equations during a maturation period in adolescent girls (12-16ys)

Validation of predicting fatness methods in the Iranian girls with respect to the maturity process could help to identify anthropometric risk factors. This study evaluate the accuracy of four body composition prediction equations in the teenager students in Hamadan city .Method: The anthropometry profile of 266 adolescent girls (12-16 ys) including ,weight (55.69±10.18 kg),body mass index (2...

متن کامل

Body composition: validity of segmental bioelectrical impedance analysis.

Bioelectrical impedance analysis (BIA) measures the impedance associated with passage of an alternating current through the body which is proportional to total body water (TBW) and therefore can provide expedient estimates of body composition. However, little validity information is available for commercially available bathroom scale type devices which perform whole body estimates from segmenta...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Nutrition

دوره 19 10  شماره 

صفحات  -

تاریخ انتشار 2003