Title: Accuracy and clinical utility of the CoaguChek XS portable international normalised ratio monitor in a pilot study of warfarin home-monitoring Running title: Evaluation of the CoaguChek XS
نویسندگان
چکیده
Aim: To evaluate the accuracy of the CoaguChek XS international normalised ratio (INR) monitor compared to the laboratory method. Methods: The accuracy and ease of use of the recently marketed CoaguChek XS portable INR monitor was evaluated in 17 patients involved in a trial of warfarin home-monitoring. INR results from the monitor were compared to the laboratory method. Clinical applicability was measured by discrepant INR values, defined in the literature by expanded and narrow agreement criteria, and by the proportion of INR values differing by more than 15% and 20% from the laboratory method. Results: Participants provided 59 comparison INR measurements for analysis. The paired results were highly correlated (r = 0.91). Expanded and narrow agreement between paired INR values occurred 100% of the time. Only three CoaguChek XS (5.1%) results differed by >15% compared to the laboratory method; no results differed by more than 20% or were more than 0.5 INR units discrepant. Conclusions: In the hands of patients the CoaguChek XS demonstrated good correlation with laboratory determination of INR and compared very well with expanded and narrow clinical agreement criteria. Both patients and doctors were highly satisfied with the accuracy and ease of use of the CoaguChek XS.
منابع مشابه
Validation of the CoaguChek XS international normalised ratio point-of-care analyser in patients at Charlotte Maxeke Johannesburg Academic Hospital, South Africa.
BACKGROUND Measurement of the international normalised ratio (INR) is essential in the management of patients on long-term warfarin therapy. The CoaguChek XS portable coagulometer is a point-of-care test for INR measurement. It offers the advantage of improved patient accessibility, particularly in peripheral clinics. OBJECTIVES To evaluate the clinical utility of the CoaguChek XS for monitor...
متن کاملClinical Utility and Accuracy of Coaguchek XS, a Reliable Alternative to Laboratory International Normalized Ratio Monitoring in Korean Patients With Atrial Fibrillation
Background and Objectives: To evaluate the accuracy and the clinical utility of the Coaguchek XS, a portable point-of-care coagulometer, compared to standard laboratory methods in Korean patients. Subjects and Methods: We included 107 patients with atrial fibrillation on long-term oral warfarin therapy. The prothrombin time as expressed by the international normalized ratio (INR) was measured b...
متن کاملSelf-monitoring of oral anticoagulation therapy in children.
This study aimed to investigate the accuracy of home International Normalized Ratio (INR) self-monitoring in pediatric patients on long-term oral anticoagulation therapy. Statistical and clinical agreement of INR values from capillary whole blood samples measured by 2 different portable prothrombin time monitors (CoaguChek S and XS) and venous blood samples measured by a laboratory coagulation ...
متن کاملAccuracy of the CoaguChek XS for point-of-care international normalized ratio (INR) measurement in children requiring warfarin.
Point-of-care INR (POC INR) meters can provide a safe and effective method for monitoring oral vitamin K antagonists (VKAs) in children. Stollery Children's Hospital has a large POC INR meter loan program for children requiring oral VKAs. Our protocol requires that POC INR results be compared to the standard laboratory INR for each child on several consecutive tests to ensure accuracy of CoaguC...
متن کاملPoint-of-care monitoring of oral anticoagulation therapy in children. Comparison of the CoaguChek XS system with venous INR and venous INR using an International Reference Thromboplastin preparation (rTF/95).
Point-of-care (POC) monitoring of oral anticoagulation has been widely adopted in both paediatric and adult patients. A new POC system, the CoaguChek XS has recently been developed to measure the international normalised ratio (INR) and may offer significant advantages. The CoaguChek XS utilises a new method of electrochemical clot detection based on thrombin generation. This system has not bee...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2006