MIQE: Guidelines for the Design and Publication of a Reliable Real-time PCR Assay
نویسندگان
چکیده
The capacity to amplify and detect trace amounts of nucleic acids has made the polymerase chain reaction (PCR) the most formidable molecular technology in use today. Its versatility and scope was further broadened first with the development of reverse transcription (RT)-PCR, which opened up the entire RNA field to thorough exploration and then, most conspicuously, with its evolution into real-time quantitative PCR (qPCR). Speed, simplicity, specificity, wide linear dynamic range, multiplexing and high-throughput potential, reduced contamination risk, simplified detection and data analysis procedures as well as availability of increasingly affordable instrumentation and reduced reagent cost have made qPCR the molecular method of choice when quantifying nucleic acids. Detection of pathogens, SNP analyses and quantification of RNA, even real-time analysis of gene expression in vivo have become routine applications and constant enhancements of chemistries, enzymes, mastermixes and instruments continue to extend the scope of qPCR technology by promising added benefits such as extremely short assay times measured in minutes, low reagent usage and exceptionally rapid heating/cooling rates. The whole process is driven by the insatiable demand for ever-more specific, sensitive, convenient and cost-effective protocols. However, it has also become clear that variable pre-assay conditions, poor assay design and incorrect data analysis have resulted in the regular publication of data that are often inconsistent, inaccurate and often simply wrong. The problem is exacerbated by a lack of transparency of reporting, with the details of technical information wholly inadequate for the purpose of assessing the validity of reported qPCR data. This has serious consequences for basic research, reducing the potential for translating findings into valuable applications and potentially devastating implications for clinical practice. In response, guidelines proposing a minimum standard for the provision of information for qPCR experiments (‘MIQE’) have been launched. These aim to establish a standard for accurate and reliable qPCR experimental design as well as recommendations to ensure comprehensive reporting of technical detail, indispensable conditions for the maturing of qPCR into a robust, accurate and reliable nucleic acid quantification technology. Introduction Quantitative real-time PCR (qPCR) has become a ubiquitous, mainstream technology widely referred to as the gold standard for nucleic acid detection and quantification in
منابع مشابه
The MIQE guidelines: minimum information for publication of quantitative real-time PCR experiments.
BACKGROUND Currently, a lack of consensus exists on how best to perform and interpret quantitative real-time PCR (qPCR) experiments. The problem is exacerbated by a lack of sufficient experimental detail in many publications, which impedes a reader's ability to evaluate critically the quality of the results presented or to repeat the experiments. CONTENT The Minimum Information for Publicatio...
متن کاملReal-time quantitative PCR, pathogen detection and MIQE.
Nucleic acids are the ultimate biomarker and real-time PCR (qPCR) is firmly established as the method of choice for nucleic acid detection. Together, they allow the accurate, sensitive and specific identification of pathogens, and the use of qPCR has become routine in diagnostic laboratories. The reliability of qPCR-based assays relies on a combination of optimal sample selection, assay design ...
متن کاملWhy the need for qPCR publication guidelines?--The case for MIQE.
The polymerase chain reaction (PCR) has matured from a labour- and time-intensive, low throughput qualitative gel-based technique to an easily automated, rapid, high throughput quantitative technology. Real-time quantitative PCR (qPCR) has become the benchmark technology for the detection and quantification of nucleic acids in a research, diagnostic, forensic and biotechnology setting. However,...
متن کاملA MIQE-Compliant Real-Time PCR Assay for Aspergillus Detection
The polymerase chain reaction (PCR) is widely used as a diagnostic tool in clinical laboratories and is particularly effective for detecting and identifying infectious agents for which routine culture and microscopy methods are inadequate. Invasive fungal disease (IFD) is a major cause of morbidity and mortality in immunosuppressed patients, and optimal diagnostic criteria are contentious. Alth...
متن کاملMinimum information necessary for quantitative real-time PCR experiments.
The MIQE (minimum information for the publication of quantitative real-time PCR) guidelines were published in 2009 with the twin aims of providing a blueprint for good real-time quantitative polymerase chain reaction (qPCR) assay design and encouraging the comprehensive reporting of qPCR protocols. It had become increasingly clear that variable pre-assay conditions, poor assay design, and incor...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -