Analysis of Building Envelope Insulation Performance Utilizing Integrated Temperature and Humidity Sensors

نویسندگان

  • San-Shan Hung
  • Chih-Yuan Chang
  • Cheng-Jui Hsu
  • Shih-Wei Chen
چکیده

A major cause of high energy consumption for air conditioning in indoor spaces is the thermal storage characteristics of a building's envelope concrete material; therefore, the physiological signals (temperature and humidity) within concrete structures are an important reference for building energy management. The current approach to measuring temperature and humidity within concrete structures (i.e., thermocouples and fiber optics) is limited by problems of wiring requirements, discontinuous monitoring, and high costs. This study uses radio frequency integrated circuits (RFIC) combined with temperature and humidity sensors (T/H sensors) for the design of a smart temperature and humidity information material (STHIM) that automatically, regularly, and continuously converts temperature and humidity signals within concrete and transmits them by radio frequency (RF) to the Building Physiology Information System (BPIS). This provides a new approach to measurement that incorporates direct measurement, wireless communication, and real-time continuous monitoring to assist building designers and users in making energy management decisions and judgments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hygric Performance of a Sandstone Wall Retrofitted with Interior Thermal Insulation

Temperature, relative humidity and overhygroscopic moisture fields in a sandstone wall provided with interior thermal insulation were calculated in order to assess the hygric performance of the retrofitted wall. Computational simulations showed that during the time period of 10 years which was subject of investigation no overhygroscopic moisture appeared in the analyzed building envelope so tha...

متن کامل

Durability of Interior Renderings in Schools: Optimization of Envelope Insulation for Mitigation of Mould Growth Risk

A high standard education is, nowadays, a clear objective for any modern society. In Portugal, the retrofit of educational buildings has an enormous relevance as demonstrated by the ‘‘Program for Retrofit and Upgrade of High Schools’’. Educational buildings specific characteristics such as high occupancy rates and high amount of time children spend in classrooms make them a special case compare...

متن کامل

Building Retrofit using Vacuum Insulation Panels Hygrothermal Performance and Durability Thesis for the Degree of Doctor of Philosophy

Many old buildings have unsatisfactory thermal performance compared to the standards of today. One way to increase the thermal performance is to add thermal insulation to the building envelope. However, many old buildings are listed and considered to be valuable for historical and esthetic reasons. This often limits the position and thickness of the additional insulation layer. Vacuum insulatio...

متن کامل

Analysis of IAQ Based on Modeling of Building Envelope Coupled with CFD&HT Room Airflow

Buildings represent a major part of the world energy requirement. The simulation of combined heat, air and moisture (HAM) and pollutant transfer in this context is important to predict the indoor air quality (IAQ), along with the thermal comfort inside the buildings. Moreover, it is important to have appropriate levels of indoor humidity along with the room temperature as movement of water vapo...

متن کامل

Heat Transfer, Environmental Benefits, and Social Cost Analysis of Different Insulation Methods by Considering Insulation Disadvantages

In this paper, the thermal performance of four common insulators in two internal and external insulation systems is investigated for the ASHRAE setpoint range by applying detailed numerical simulation and Anti-Insulation phenomenon. Anti-Insulation phenomenon and consequent extra load on the HVAC system can occur following the thermal insulation of a building if proper temperature setpoint is n...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2012