99mTc-HEPIDA hepatic clearance as a diagnostic tool: usefulness of plasma and hepatic clearance for assessment of hepatic parenchyma performance.

نویسندگان

  • Izabela Frieske
  • Marian J Surma
  • Małgorzata Bieńkiewicz
  • Jolanta Białkowska-Warzecha
  • Julian Liniecki
  • Jan Kuydowicz
  • Jacek Kuśmierek
چکیده

Plasma clearance of (99m)Tc-HEPIDA (Cl(Pl)) has been used for two decades for assessment of liver function in patients with diseases of this organ. A specific determination of (99m)Tc-HEPIDA liver clearance (Cl(Hp)) has been developed that provides more direct possibility to evaluate performance of liver parenchyma. Both tests have been studied in healthy volunteers of varying age (48 individuals) and in 83 patients with varying degree of liver damage. The liver damage has been evaluated on the basis of 5 biochemical tests (AspAT, ALAT, GGTP, bilirubine serum concentration, proteinogram) and a score system used for total impairment, which was calculated for each patient. Normal range of Cl(Pl) and Cl(Hp) was determined from a study on healthy individuals (volunteers). The results seem independent of age, but show sex differences. The following values (mean +/- SD) of Cl(Hp) were found in males and females of: (181 +/- 31) ml//min/1.73 m(2) and (158 +/- 22) ml/min/1.73m(2), and of Cl(Pl) were (224 +/- 33) ml/min/1.73 m(2) and (202 +/- 25) ml/min/1.73 m(2) respectively. Accepted lower boundaries of both quantities (mean -2SD) are 115 ml/min/1.73 m(2) and 150 ml/min/1.73 m(2) correspondingly. Negative correlation of individual values of both clearances in all patients with individual score of liver damage were highly significant and correlation coefficients obtained were higher for Cl(Hp) (r = -0.63) than those for Cl(Pl) (r= -0.56). Factorial analysis was performed with the intention of seeing which of the studied factors had the highest factor loading for parenchyma performance that was assumed as the common factor responsible for correlations. The highest value was obtained for hepatic clearance (Cl(Hp)) of (99m)Tc-HEPIDA. In conclusion this quantity seems highly promising as a clinically useful test for assessment of liver performance, both in screening for liver damage and for monitoring of organ conditions during therapy and follow-up of patients.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Orexin-A Improves Hepatic Injury Following Renal Ischemia Reperfusion in Rats

Introduction: Orexins are novel neuropeptides that are localized in neurons in the lateral hypothalamus. They are implicated in a wide variety of physiological functions. Orexin peptides and receptors are found in many peripheral organs such as kidneys. It has been demonstrated that exogenous orexin-A can induce protective effects against ischemia–reperfusion injury in many organs. The goal ...

متن کامل

Assessment of accuracy and precision of 99 mTc

BACKGROUND: The aim of the present study was the assessment of the accuracy and precision of our own simplified method for the determination of 99mTc-HEPIDA liver clearance. MATERIAL AND METHODS: It has been assumed that archived results of plasma clearance (ClPl) and hepatic (ClHp), determined by means of multisample methods, could be legitimately used as a reference standard. The accuracy and...

متن کامل

Uncertainty analysis of (99m)Tc-HEPIDA liver clearance determination.

BACKGROUND The aim of the study was to obtain information on the accuracy and precision of (99m)Tc-HEPIDA hepatic (Cl(Hp)) and plasma (Cl(Pl)) clearances and selection of an appropriate estimator of the measurement uncertainty of a single determination of these quantities. MATERIAL AND METHODS In a simulation (Monte Carlo) experiment, it was assumed that the recorded results of plasma and hep...

متن کامل

Asialoglycoprotein receptor concentration in tumor-bearing livers and its fate early after their sectorial resection.

UNLABELLED The aim of the present study was to investigate asialoglycoprotein receptor (ASGP-R) status in tumor-bearing livers and early after their sectorial resection employing 99mTc-DTPA-galactosyl human serum albumin (99mTc-GSA) dynamic SPECT. METHODS Ten normal liver controls and 44 liver tumor patients who underwent sectorial hepatectomy were included in the study. 99mTc-GSA dynamic SPE...

متن کامل

A camera based calculation of 99mTc-MAG3 clearance using conjugate views method [Persian]

Background: Measurement of absolute or differential renal function using radiotracers plays an important role in the clinical management of various renal diseases. Gamma camera quantitative methods in approximation of renal clearance may potentially be as accurate as plasma clearance methods. However some critical factors such as kidney depth and background counts are still troublesome in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Nuclear medicine review. Central & Eastern Europe

دوره 6 1  شماره 

صفحات  -

تاریخ انتشار 2003