Electromagnetic properties of the Dayem bridge

نویسنده

  • M. T. Levinsen
چکیده

2014 The first measurements on the Dayem bridge showed that the behaviour in an applied microwave field was quite different from that of the Josephson tunnel junction. Measurements on bridges one magnitude smaller later showed this difference to result from the bridge size. A very simple equivalent circuit was furthermore shown to characterize these small bridges. Analog computer calculations on this circuit will be compared to experimental results. At high temperatures a rounding of steps and supercurrent presumably due to noise is observed. A comparison with the theory of Ambegaokar and Halperin will be presented. At low temperatures a hysteresis develops. This may result from the bridge capacitance which also may give rise to subharmonic steps. However, the magnitude (1 pF) inferred from the hysteresis is too small to account for the subharmonic steps actually observed. In contrast to other types of junctions the bridge is mechanically very robust. We have therefore been interested in the applicability of the bridge. An upper limit to the sensitivity to 10 GHz radiation has been found in terms of NEP to 9 10-14 W/~Hz. Furthermore, we have demonstrated that mixing via the Josephson effect is possible. The power dependence of the sum and difference steps is in fair agreement with analog computer calculations on the equivalent circuit. It has been debated whether the bridge radiates at all. By the observation of a cavity induced step we have now established that bridges do radiate. MICROBRIDGE PROPERTIES

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microwave generation and complex microwave responsivity measurements on small Dayem bridges

Measurements of the active properties of a Dayem micro-bridge at X-band frequencies is described. The bridge was mounted in a microwave cavity designed to match the bridge properly and the microwave output from the cavity was detected using a sensitive X-band spectrometer. Micsowave power was detected from the freely running Josephson oscillations with the bridge dc-biased to emit at the receiv...

متن کامل

Analysis and Simulation of ZVS Methods in Full Bridge Converters and Realization of a 3 KW Prototype

One of the difficulties with PWM switching converters is high switching loss and electromagnetic interference due to switching at non-zero voltage and current, which limits the operating frequency. In order to reduce the converter volume and weight (by increasing the frequency) and reducing switching losses, zero voltage and current switching methods are recommended. In this paper, four main ze...

متن کامل

Analysis and Simulation of ZVS Methods in Full Bridge Converters and Realization of a 3 KW Prototype

One of the difficulties with PWM switching converters is high switching loss and electromagnetic interference due to switching at non-zero voltage and current, which limits the operating frequency. In order to reduce the converter volume and weight (by increasing the frequency) and reducing switching losses, zero voltage and current switching methods are recommended. In this paper, four main ze...

متن کامل

Electrical and electromagnetic properties of isolated carbon nanotubes and carbon nanotube-based composites

Isolated carbon nanotubes (CNTs), CNT films and CNT-polymer nanocomposites are a new generation of materials with outstanding mechanical, thermal, electrical and electromagnetic properties. The main objective of this article is to provide a comprehensive review on the investigations performed in the field of characterizing electrical and electromagnetic properties of isolated CNTs and CNT-reinf...

متن کامل

Effect of carbon black content on the microwave absorbing properties of CB/epoxy composites

To prevent serious electromagnetic interference, a single-layer and double layer wave-absorbing coating employing complex absorbents composed of carbon black with epoxy resin as matrix was prepared. The morphologies of carbon black /epoxy composites were characterized by scanning electron microscope  and atomic force microscope, respectively. The carbon black  particles exhibit obvious polyarom...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016