Extended support with the Terumo Baby-RX oxygenator.

نویسندگان

  • Joseph J Deptula
  • Sherrie K Fogg
  • Kimberly R Glogowski
  • Kathleen N Fenton
  • Kim F Duncan
چکیده

The Terumo Baby-RX, a new-generation low prime oxygenator, recently has entered the perfusion market in North America. This oxygenator is designed exclusively for neonates and infants and has the smallest priming volume of any clinically available oxygenator. The BABY-RX also is treated with X Coating, Terumo's biocompatible, hydrophilic polymer surface coating that reduces platelet adhesion and protein denaturation. The oxygenator has a blood flow range of 0.1 to 1500 mL/min and operates with a minimum reservoir volume of 15 mL. A 3.2-kg patient, status post-Stage 1 Norwood, Palliation was placed on cardiopulmonary support after thrombus formation within the modified Blalock-Taussig shunt during a general surgery procedure. The extended support circuit incorporated the Baby-RX oxygenator for 17.5 hours. The oxygenator performed well over this time period at flows of 600-800 mL/min, sweep rates of 100-300 mL/min, FiO2 of 30-40%, and ACTs of 140-200 seconds. There were no indices of oxygenator failure noted within the time frame of support. After placement of a new systemic to pulmonary shunt, the patient was removed from support and the oxygenator drained of residual blood. No evidence of fiber damage or clot formation was noted. The patient had a successful support run without complications related to cardiopulmonary support.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vitro drug adsorption and plasma free hemoglobin levels associated with hollow fiber oxygenators in the extracorporeal life support (ECLS) circuit.

The purpose of this study was to identify the percentage of fentanyl or morphine sulfate lost from adhesion to either the polyvinylchloride (PVC) tubing or the surface of two different hollow fiber oxygenators used in current extracorporeal life support circuits and to identify any difference in the plasma free hemoglobin (PFH) levels generated when using these oxygenator and/or drug combinatio...

متن کامل

Randomized trial of the Terumo Capiox FX05 oxygenator with integral arterial filter versus Terumo Capiox Baby RX05 and Terumo Capiox AF02 arterial filter in infants undergoing cardiopulmonary bypass.

UNLABELLED The purpose of this clinical trial was to evaluate the effect of the Terumo Capiox FX05 oxygenator with integrated arterial filter during cardiopulmonary bypass (CPB) compared with the Terumo Capiox RX05 Baby RX and arterial filter on inflammatory mediators and blood product utilization. Forty patients weighing less than 10 kg who underwent congenital heart surgery utilizing cardiopu...

متن کامل

In vitro evaluation of gaseous microemboli handling of cardiopulmonary bypass circuits with and without integrated arterial line filters.

The delivery of gaseous microemboli (GME) by the cardiopulmonary bypass circuit should be minimized whenever possible. Innovations in components, such as the integration of arterial line filter (ALF) and ALFs with reduced priming volumes, have provided clinicians with circuit design options. However, before adopting these components clinically, their GME handling ability should be assessed. Thi...

متن کامل

A clinical evaluation of the Terumo Capiox SX18R hollow fiber oxygenator.

The Terumo Capiox SX18R is a commercially available, low prime, reverse phase, hollow fiber membrane oxygenator. The oxygenator consists of a 1.8 m2 microporous polypropylene hollow fiber bundle, a 2200 cm2 tubular stainless steel heat exchanger, and an open hard shell venous reservoir with integral cardiotomy filter. The Terumo Capiox SX18R oxygenator was evaluated to determine its clinical ox...

متن کامل

Disconnection of Cobe SMARxT tubing from the venous outlet of the Terumo Capiox SX25RX oxygenator during cardiopulmonary bypass.

The use of surface modified, biocompatible tubing in cardiopulmonary bypass has been reported to decrease the inflammatory responses caused by blood contact with the non endothelial surface of poly vinyl chloride (PVC) tubing. The combination of advances in biocompatible tubing and increased affordability resulted in a change to our cardiopulmonary bypass circuit, with the Terumo Capiox SX25 ox...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The journal of extra-corporeal technology

دوره 36 4  شماره 

صفحات  -

تاریخ انتشار 2004