How Do Vents Affect Hearing Aid Performance?

ثبت نشده
چکیده

with an occluding earmold; data above “0” suggest a gain increase (from resonance) while that below “0” suggest gain reduction with the specific vent dimension (length and diameter). The solid line shows the result of a 6 mmlong vent, while the dotted line shows that of a 22 mm-long vent. For both vent lengths, one sees more low-frequency gain reduction as the vent diameter increases. For example, one sees that the output at 200 Hz is reduced by 7-8 dB with a 1 mm vent diameter, but as much as 28 dB reduction with a 3 mm vent diameter. Thus, an increase in vent diameter leads to a reduction in low frequency output below 1000 Hz. A vent is a tube. As such, it is subject to tubing resonance. Figure 2 also shows that a change in vent diameter leads to a shift in the ventassociated resoW e typically consider sounds at the eardrum to be a function of the output of the hearing aid moderated by the residual volume between the tip of the hearing aid/earmold and the eardrum. To a large extent, this is true for an occluding hearing aid (one without any vents or leakage) and when the wearer listens to sounds from their environments. On the other hand, with a vented hearing aid and when the wearer talks, the overall sound pressure level at the eardrum also includes direct sounds that enter (or leave) through the vents (and any unintentional leakage) and bone-conducted sounds generated from the wearer’s voice. The contribution of each source varies depending on the state of the wearer (speaking versus listening) and the size of the leakage (or venting), in addition to the gain settings on the hearing aid. Figure 1 shows a simplified diagram of the three sources of sound. In the extreme case of someone with a high frequency hearing loss who is speaking while wearing a closed earmold, the low frequency SPL at the eardrum is dominated by the bone-conducted sounds. In an open-fitting situation, sounds entering directly through the vent opening will have a larger contribution to the SPL at the eardrum.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hearing Aid Effect on Elderly's Depression in Tehran's Nursing Homes

Objectives: Moderate hearing impairment in older age can affect physical and psychosocial health of people. The rate of isolation, lack of self confidence, depression and probably dementia in this people is high. This study was conducted to study the hearing aid effect on older adults depression in tehran nursing homes. Methods & Materials: In this study depression was assessed in 3 groups o...

متن کامل

Satisfaction with Hearing Aids Based on Technology and Style among Hearing Impaired Persons

Introduction: Hearing loss is one of the most disabling impairments. Using a hearing aid as an attempt to improve the hearing problem can positively affect the quality of life for these people. This research was aimed to assess satisfaction of hearing impaired patients with their hearing aids regarding the employed technology and style.   Materials and Methods: This descriptive-analytic cross-s...

متن کامل

Spatial Design of Hearing Aids Incorporating Multiple Vents

The main aim of this study was to investigate the shape variation in the human ear canal and the effects of venting on the spatial design of hearing aids. The second aim was to determine the design feasibility of a multiple venting hearing aid and assess the flexibility of design provided. A statistical shape model based on principal component analysis was created from a dataset of 60 left and ...

متن کامل

Open Versus Closed Hearing-Aid Fittings: A Literature Review of Both Fitting Approaches

One of the main issues in hearing-aid fittings is the abnormal perception of the user's own voice as too loud, "boomy," or "hollow." This phenomenon known as the occlusion effect be reduced by large vents in the earmolds or by open-fit hearing aids. This review provides an overview of publications related to open and closed hearing-aid fittings. First, the occlusion effect and its consequences ...

متن کامل

Occlusion effect of earmolds with different venting systems.

In this study the occlusion effect was quantified for five types of earmolds with different venting. Nine normal-hearing listeners and ten experienced hearing aid users were provided with conventional earmolds with 1.6 and 2.4 mm circular venting, shell type earmolds with a novel vent design with equivalent cross-sectional vent areas, and nonoccluding soft silicone eartips of a commercial heari...

متن کامل