Safety, hemodynamic profile, and feasibility of dobutamine stress technetium myocardial perfusion single-photon emission CT imaging for evaluation of coronary artery disease in the elderly.
نویسندگان
چکیده
OBJECTIVES Cardiovascular disease is the leading cause of morbidity and mortality in the elderly. The evaluation of coronary artery disease by exercise stress testing is frequently limited by the patient's inability to exercise. Although pharmacologic stress testing with dobutamine is an alternative, the safety of dobutamine myocardial perfusion scintigraphy in the elderly has not been previously studied. PATIENTS AND METHODS We studied the safety and feasibility of dobutamine (up to 40 microg/kg/min)-atropine (up to 1 mg) stress myocardial perfusion scintigraphy using technetium single-photon emission CT imaging in 227 patients > or = 70 years old (mean +/- SD age, 75 +/- 4 years). A control group of 227 patients < 70 years old (mean age, 55 +/- 11 years; matched for gender, prevalence of previous infarction, beta-blocker therapy, and severity of resting perfusion abnormalities) was studied to assess age-related differences in the safety and the hemodynamic response. A feasible test was defined as the achievement of the target heart rate and/or an ischemic end point (angina, ST-segment depression, or reversible perfusion abnormalities). RESULTS No myocardial infarction or death occurred during the test. The target heart rate was achieved more frequently in the elderly patients (87% vs 79%; p < 0.05). The elderly patients had a higher prevalence of supraventricular tachycardia (7% vs 1%; p < 0.005) and premature ventricular contraction (74% vs 32%; p < 0.005) during the test, as compared to the younger patients. There was a trend to a higher prevalence of ventricular tachycardia (5% vs 2%) and atrial fibrillation (3% vs 0.4%) in the elderly patients. Arrhythmias were terminated spontaneously by termination of dobutamine infusion or by administration of metoprolol. Independent predictors of supraventricular tachyarrhythmias and ventricular tachycardia were older age (p < 0.001; chi(2), 9.8) and myocardial perfusion defect score at rest (p < 0.01; chi(2), 6.8) respectively, by using a multivariate analysis of clinical and stress test variables. Elderly patients had a higher prevalence of systolic BP drop > 20 mm Hg during the test (37% vs 12%; p < 0.05). The test was terminated due to hypotension in 2% of the elderly patients and in 1% of the control group. Age was the most powerful predictor of hypotension (p < 0.005; chi(2), 10.3). The test was considered feasible in 216 elderly patients (95%) and in 209 patients of the control group (92%). CONCLUSION Dobutamine-atropine stress myocardial perfusion scintigraphy is a highly feasible method for the evaluation of coronary artery disease in the elderly. Elderly patients have a higher risk for developing hypotension and supraventricular tachyarrhythmias during a dobutamine stress test. However, dobutamine-induced hypotension is often asymptomatic and rarely necessitates the termination of the test.
منابع مشابه
Phase II Safety and Clinical Comparison With Single-Photon Emission Computed Tomography Myocardial Perfusion Imaging for Detection of Coronary Artery Disease
Objectives This was a phase II trial to assess flurpiridaz F 18 for safety and compare its diagnostic performance for positron emission tomography (PET) myocardial perfusion imaging (MPI) with Tc-99m single-photon emission computed tomography (SPECT) MPI with regard to image quality, interpretative certainty, defect magnitude, and detection of coronary artery disease (CAD) ( 50% stenosis) on in...
متن کاملPrediction of Changes in Left Ventricular Ejection Fraction after Off-Pump Coronary Artery Bypass Grafting Surgery by Myocardial Perfusion Single-Photon Emission Computed Tomography
Introduction: Left ventricular ejection fraction (LVEF) is considered to be the single most important prognostic factor in patients with previous myocardial infarction. LVEF is not improved in all patients after coronary artery bypass grafting (CABG). This study aimed to assess the possibility of prediction of LVEF changes after CABG using myocardial perfusion gated signle photon emission compu...
متن کاملCONTINUING EDUCATION Dobutamine Stress Myocardial Perfusion Imaging in Coronary Artery Disease*
The accurate noninvasive diagnosis and functional evaluation of coronary artery disease is an important step in selecting the appropriate management strategy. Dobutamine stress myocardial perfusion imaging is an alternative to exercise in patients with limited exercise capacity. In many centers, the test is performed on patients who have a contraindication for vasodilator stress testing. Recent...
متن کاملContrast Echocardiography: A New Method for the Assesment of Myocardial Perfusion in Coronary Artery Disease
highly suited to the non-invasive assessment of myocardial function. Changes in myocardial perfusion can be depicted by echocardiography indirectly as wall motion and thickening abnormalities. Regional left ventricular systolic function estimation is useful in the detection of ischemic but viable myocardium and provides information of paramount importance concerning the management of patients w...
متن کاملDobutamine stress myocardial perfusion imaging in coronary artery disease.
The accurate noninvasive diagnosis and functional evaluation of coronary artery disease is an important step in selecting the appropriate management strategy. Dobutamine stress myocardial perfusion imaging is an alternative to exercise in patients with limited exercise capacity. In many centers, the test is performed on patients who have a contraindication for vasodilator stress testing. Recent...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Chest
دوره 117 3 شماره
صفحات -
تاریخ انتشار 2000