The Phadebact Gonococcus Test, a coagglutination procedure for the confirmation of identity of presumptive N gonorrhoeae isolates, was evaluated under normal working conditions in a routine diagnostic laboratory and compared with an immunofluorescence technique. Of 166 isolates of N gonorrhoeae from urogenital, rectal, and pharyngeal sites, 164 gave a positive coagglutination reaction, and one of the two negative isolates gave a positive reaction on retesting after subculture. There were no cross-reactions with other organisms tested. This was in contrast with the immunofluorescence technique; with this method, three of 46 isolates of N meningitidis fluoresced brightly, and a further 17 isolates of N meningitidis gave reactions that were difficult to interpret. The coagglutination test is rapid, simple and a more specific alternative to immunofluorescence.
منابع مشابه
Evaluation of the Phadebact Test for identification of Neisseria gonorrhoeae.
The Phadebact Gonococcus Test (Pharmacia Diagnostics, Piscataway, N.J.) is used for the identification of Neisseria gonorrhoeae. In this test, boiled organisms are examined by using a 3-min coagglutination technique. A total of 313 isolates of Neisseria confirmed by the fluorescent-antibody technique or identified to the species level by the cysteine-tryptose agar utilization technique, were te...
متن کاملRapid laboratory identification of Neisseria gonorrhoeae by coagglutination.
We compared the Phadebact Gonococcus Test with conventional methods in identifying 210 strains of Neisseria gonorrhoeae. Of these, 209 strains were correctly identified (99.5%).
متن کاملEvaluation of the Phadebact Gonococcus Test for confirmation of Neisseria gonorrhoeae.
Strains of Neisseria gonorrhoeae grown on Thayer-Martin medium and media with and without serum were examined by the Phadebact Gonococcus Test. By using the direct method, in which colonies from growth media were mixed directly with the reagents on a microscope slide, Thayer-Martin medium, contrary to the manufacturer's claim, was not found to be the medium giving best results, and presence or ...
متن کاملComparison of a slide coagglutination technique with the Minitek system for confirmation of Neisseria gonorrhoeae.
The Phadebact gonococcus test was performed on 314 bacterial isolates to compare the coagglutination technique with the Minitek system for the confirmation of Neisseria gonorrhoeae. Direct testing, using colonies of N. gonorrhoeae mixed with the Phadebact gonococcus test reagents, produced noninterpretable results in many cases. However, an alternative method, described by the manufacturer, of ...
متن کاملEvaluation of the RIM-N, Gonochek II, and Phadebact systems for the identification of pathogenic Neisseria spp. and Branhamella catarrhalis.
Methods for identifying Neisseria spp. include conventional and modified carbohydrate degradation procedures, chromogenic enzyme substrate tests, and immunologic coagglutination tests for Neisseria gonorrhoeae. In this study, we evaluated the abilities of the RIM-N carbohydrate degradation system (American MicroScan, Campbell, Calif.), the Gonochek II enzymatic identification system (Du Pont Co...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of clinical pathology
دوره 34 10 شماره
صفحات -
تاریخ انتشار 1981