Certification of butyltins and phenyltins in marine sediment certified reference material by species-specific isotope-dilution mass spectrometric analysis using synthesized 118Sn-enriched organotin compounds
نویسندگان
چکیده
A new marine sediment certified reference material, NMIJ CRM 7306-a, for butyltin and phenyltin analysis has been prepared and certified by the National Metrological Institute of Japan at the National Institute of Advanced Industrial Science and Technology (NMIJ/AIST). Candidate sediment material was collected at a bay near industrial activity in Japan. After air-drying, sieving, and mixing the material was sterilized with gamma-ray irradiation. The material was re-mixed and packaged into 250 glass bottles (15 g each) and these were stored in a freezer at -30 degrees C. Certification was performed by use of three different types of species-specific isotope-dilution mass spectrometry (SSID-MS)-SSID-GC-ICP-MS, SSID-GC-MS, and SSID-LC-ICP-MS, with 118Sn-enriched organotin compounds synthesized from 118Sn-enriched metal used as a spike. The 118Sn-enriched mono-butyltin (MBT), dibutyltin (DBT), and tributyltin (TBT) were synthesized as a mixture whereas the 118Sn-enriched di-phenyltin (DPhT) and triphenyltin (TPhT) were synthesized individually. Four different extraction methods, mechanical shaking, ultrasonic, microwave-assisted, and pressurized liquid extraction, were adopted to avoid possible analytical bias caused by non-quantitative extraction and degradation or inter-conversion of analytes in sample preparations. Tropolone was used as chelating agent in all the extraction methods. Certified values are given for TBT 44+/-3 microg kg(-1) as Sn, DBT 51 +/- 2 microg kg(-1) as Sn, MBT 67 +/- 3 microg kg(-1) as Sn, TPhT 6.9 +/- 1.2 microg kg(-1) as Sn, and DPhT 3.4 +/- 1.2 microg kg(-1) as Sn. These levels are lower than in other sediment CRMs currently available for analysis of organotin compounds.
منابع مشابه
Organotins in the sediments of the Zuari estuary, west coast of India.
Industrial use of organotins such as butyltins and phenyltins has increased several folds during the last two decades. Butyltins and phenyltins are synthetic, multipurpose chemicals, which have been extensively used in marine antifouling paints. They have been known to be extremely poisonous to mollusc fishery resources (oysters, clams, etc.). Contamination of Zuari estuary sediments was assess...
متن کاملButyltin compounds in a sediment core from the old Tilbury basin, London, UK.
Sections from a sediment core taken from the River Thames were analysed for butyltin species using gas chromatography with species-specific isotope dilution mass spectrometry. Results demonstrated that in most samples tributyltin concentrations of 20-60 ng/g accounted for <10% of the total butyltin species present, which is in agreement with data from other sediment samples which were historica...
متن کاملEvaluation of accelerated solvent extraction for butyltin speciation in PACS-2 CRM using double-spike isotope dilution-GC/ICPMS.
Pressurized liquid extraction using the accelerated solvent extractor (Dionex ASE 200) has been evaluated for the determination of mono-, di- and tributyltin (MBT, DBT, and TBT, respectively) in PACS-2 certified reference material. A double-enriched spike containing 119Sn-enriched MBT and TBT and 118Sn-enriched DBT allowed for the simultaneous determination of the three butyltin species and the...
متن کاملDevelopment of a Certified Reference Material for the Analysis of Vitamins in Infant Formula
An infant formula certified reference material (CRM) for the analysis of vitamins was developed. Vitamin A, folic acid, niacin, were certified and their stability has been monitored by using isotope dilution-liquid chromatography/mass spectrometric (ID-LC/MS) methods developed in our laboratories as primary methods for the corresponding analytes. Certification of α-, δ-, and γtocopherols in the...
متن کاملA Comparison of GC-ICP-MS and HPLC-ICP-MS for the Analysis of Organotin Compounds Application
An inductively coupled plasma mass spectrometer (ICP-MS) was used as a detector for gas chromatography (GC) and high performance liquid chromatography (HPLC) analysis of organotin compounds. ICP-MS is a highly sensitive detector with detection limits in the pg ng range, as well as enabling calibration by isotope dilution mass spectrometry (IDMS). Calibrating using isotopically labeled organotin...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Analytical and Bioanalytical Chemistry
دوره 387 شماره
صفحات -
تاریخ انتشار 2007