Noise Removal Applied to a Temperature Signal from Body and Seat Contact Surface Based on the EMD Method

نویسندگان

  • Zhuofu Liu
  • Zhongming Luo
  • Jiang Wei
  • Meimei Liu
  • Tianye Chen
  • Liang Chen
  • Andrew I Heusch
  • Vincenzo Cascioli
  • Peter W McCarthy
چکیده

People today spend longer seated resulting from changes in demand on the workforce. As a result there is a need for a greater understanding of factors affecting pressure sore formation and comfort in general. In order to monitor the body-cushion interface temperature, we have developed a portable five-channel temperature measuring system which can be powered by a laptop. An Empirical Mode Decomposition (EMD) was used to remove noise of thermal data between body and seat contact surface. The performance of this data driven filter was compared with three other filters (medium filter, adaptive filter and wavelet filter) with the help of the goodness of fitness statistics as judgment criteria. Results showed the EMD-based filter worked better than traditional de-noising algorithms with the lowest RMSE (root-mean-square-error) and the highest R values.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Adaptive Filtering Strategy to Remove Noise from ECG Signals Using Wavelet Transform and Deep Learning

Introduction: Electrocardiogram (ECG) is a method to measure the electrical activity of the heart which is performed by placing electrodes on the surface of the body. Physicians use observation tools to detect and diagnose heart diseases, the same is performed on ECG signals by cardiologists. In particular, heart diseases are recognized by examining the graphic representation of heart signals w...

متن کامل

Adaptive Filtering Strategy to Remove Noise from ECG Signals Using Wavelet Transform and Deep Learning

Introduction: Electrocardiogram (ECG) is a method to measure the electrical activity of the heart which is performed by placing electrodes on the surface of the body. Physicians use observation tools to detect and diagnose heart diseases, the same is performed on ECG signals by cardiologists. In particular, heart diseases are recognized by examining the graphic representation of heart signals w...

متن کامل

EEG Artifact Removal System for Depression Using a Hybrid Denoising Approach

Introduction: Clinicians use several computer-aided diagnostic systems for depression to authorize their diagnosis. An electroencephalogram  (EEG) may be used as an objective tool for early diagnosis of depression and controlling it from reaching a severe and permanent state. However, artifact contamination reduces the accuracy in EEG signal processing systems. Methods: This work proposes a no...

متن کامل

Removing ECG Artifact from the Surface EMG Signal Using Adaptive Subtraction Technique

Background: The electrocardiogram artifact is a major contamination in the electromyogram signals when electromyogram signal is recorded from upper trunk muscles and because of that the contaminated electromyogram is not useful.Objective: Removing electrocardiogram contamination from electromyogram signals.Methods: In this paper, the clean electromyogram signal, electrocardiogram artifact and e...

متن کامل

Studies on optimization of efficient parameters for removal of lead from aqueous solutions by natural zeolite as a low-cost adsorbent using response surface methodology

In this research, the removal of lead from the aqueous solution was investigated using natural nontoxic zeolite (clinoptilolite) as a low-cost adsorbent in order to reduce human exposure to it. The clinoptilolite zeolite obtained from the Semnan area was characterized by X-ray diffraction pattern, FTIR spectroscopy and scanning electron microscopy (SEM). The central composite design (CCD) defin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013