BACKGROUND The real-time and continuous assessment of left ventricular (LV) myocardial contractility through an implanted device is a clinically relevant goal. Transvalvular impedance (TVI) is an impedentiometric signal detected in the right cardiac chambers that changes during stroke volume fluctuations in patients. However, the relationship between TVI signals and LV contractility has not been proven. We investigated whether TVI signals predict changes of LV inotropic state during clinically relevant loading and inotropic conditions in swine normal heart. METHODS The assessment of RVTVI signals was performed in anesthetized adult healthy anesthetized pigs (n = 6) instrumented for measurement of aortic and LV pressure, dP/dtmax and LV volumes. Myocardial contractility was assessed with the slope (Ees) of the LV end systolic pressure-volume relationship. Effective arterial elastance (Ea) and stroke work (SW) were determined from the LV pressure-volume loops. Pigs were studied at rest (baseline), after transient mechanical preload reduction and afterload increase, after 10-min of low dose dobutamine infusion (LDDS, 10 ug/kg/min, i.v), and esmolol administration (ESMO, bolus of 500 µg and continuous infusion of 100 µg·kg-1·min-1). RESULTS We detected a significant relationship between ESTVI and dP/dtmax during LDDS and ESMO administration. In addition, the fluctuations of ESTVI were significantly related to changes of the Ees during afterload increase, LDDS and ESMO infusion. CONCLUSIONS ESTVI signal detected in right cardiac chamber is significantly affected by acute changes in cardiac mechanical activity and is able to predict acute changes of LV inotropic state in normal heart.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effects of halothane on the interactions between myocardial contractility, aortic impedance, and left ventricular performance. I. Theoretical considerations and results.

The effects of halothane (1.0-1.5%) on myocardial contractility, systemic vascular resistance (representing the majority of impedance to oscillatory flow), and left ventricular performance, and the interactions of these functions have been studied in openchested dogs, artificially ventilated and maintained in a state of basal narcosis with chloralose and urethane. Halothane reversibly depressed...

متن کامل

COMPARISON BETWEEN THE EFFECTS OF 5 PERCENT HYPERTONIC SODIUM CHLORIDE SOLUTION AND 0.9 PERCENT SODIUM CHLORIDE SOLUTION ON LEFT VENTRICUL AR CONTRACTION

Hypertonic saline solution can absorb part of the intracellular fluid volume into the extracellular space. The effects of this solution on the cardiovascular system are increased coronary flow and increased left ventricular contraction, without sympathetic system activation. This study was designed to assess the effects of hypertonic saline solution in open heart surgery and to compare it w...

متن کامل

Cardioprotective effect of aqueous extract of Chichorium intybus L. on ischemia-reperfusion injury in isolated rat heart

Objective: Several studies have shown that Chichorium intybus L. (C. intybus) which possesses flavonoid compounds has an effective role in treatment of cardiovascular diseases. Contractile dysfunction mostly occurs after acute myocardial infarction, cardiac bypass surgery, heart transplantation and coronary angioplasty. The aim of the present study was to investigate the effect of aqueous extra...

متن کامل

Cardiac power integral: a new method for monitoring cardiovascular performance

Cardiac power (PWR) is the continuous product of flow and pressure in the proximal aorta. Our aim was to validate the PWR integral as a marker of left ventricular energy transfer to the aorta, by comparing it to stroke work (SW) under multiple different loading and contractility conditions in subjects without obstructions in the left ventricular outflow tract. Six pigs were under general anesth...

متن کامل

Adaptation to acute pulmonary hypertension in pigs

The extent of right ventricular compensation compared to the left ventricle is restricted and varies among individuals, which makes it difficult to define. While establishing a model of acute pulmonary hypertension in pigs we observed two different kinds of compensation in our animals. Looking deeper into the hemodynamic data we tried to delineate why some animals could compensate and others co...