Design and implementation of a portable physiologic data acquisition system.

نویسندگان

  • Kevin Vinecore
  • Mateo Aboy
  • James McNames
  • Charles Phillips
  • Rachel Agbeko
  • Mark Peters
  • Miles Ellenby
  • Michael L McManus
  • Brahm Goldstein
چکیده

OBJECTIVE To describe and report the reliability of a portable, laptop-based, real-time, continuous physiologic data acquisition system (PDAS) that allows for synchronous recording of physiologic data, clinical events, and event markers at the bedside for physiologic research studies in the intensive care unit. DESIGN Descriptive report of new research technology. SETTING Adult and pediatric intensive care units in three tertiary care academic hospitals. PATIENTS Sixty-four critically ill and injured patients were studied, including 34 adult (22 males and 12 females) and 30 pediatric (19 males and 11 females). INTERVENTIONS None. MEASUREMENTS AND MAIN RESULTS Data transmission errors during bench and field testing were measured. The PDAS was used in three separate research studies, by multiple users, and for repeated recordings of the same set of signals at various intervals for different lengths of time. Both parametric (1 Hz) and waveform (125-500 Hz) signals were recorded and analyzed. Details of the PDAS components are explained and examples are given from the three experimental physiology-based protocols. Waveform data include electrocardiogram, respiration, systemic arterial pressure (invasive and noninvasive), oxygen saturation, central venous pressure, pulmonary arterial pressure, left and right atrial pressures, intracranial pressure, and regional cerebral blood flow. Bench and field testing of the PDAS demonstrated excellent reliability with 100% accuracy and no data transmission errors. The key feature of simultaneously capturing physiologic signal data and clinical events (e.g., changes in mechanical ventilation, drug administration, clinical condition) is emphasized. CONCLUSIONS The PDAS provides a reliable tool to record physiologic signals and associated clinical events on a second-to-second basis and may serve as an important adjunctive research tool in designing and performing clinical physiologic studies in critical illness and injury.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Designing the infrastructure model required for the implementation of knowledge management system in the international marketing sector of the oil industry

The purpose of this study is to design the infrastructure model required for the implementation of knowledge management system in the international marketing of the oil industry. Since in applied research, the main goal is not only scientific discovery, but also to test and study the application of knowledge, so the method of this research is applied in terms of purpose and has been done by exp...

متن کامل

Design and Implementation of Portable Data Acquisition Unit in Process Control and Supervision Applications

Paper deals with design and implementation of portable data acquisition unit based on 8-bit microcontroller Freescale 68HC908GP32 in process control and supervision applications. Its hardware design is adopted to fulfill high reliability and immunity against industrial environment, high precision and compact dimensions. Communication with supervision system is performed via standard RS232 inter...

متن کامل

Design and Implementation of an Intelligent Photogrammetric System for Control and Guidance of Reconstructive Surgery

The digital image contains efficient and useful information which enables measurement and data acquisition. One of the methods that facilitate measuring and interpreting objects, using the image solely, is close-range photogrammetry. Among the various fields of science, whenever a precise measurement is required, this approach can be applied. One of these fields is Medical Sciences that due to ...

متن کامل

چالش‌های برنامه زایمان فیزیولوژیک از دیدگاه ارایه‌دهندگان خدمت: مطالعه کیفی

Background & Aim: The physiologic childbirth program in Iran is an emerging program that needs to be evaluated like any other program to improve its quality and process. Evidence suggests that the implementation of the physiologic childbirth program faces some challenges. The present research aimed to explore the challenges of the physiologic childbirth program from the perspective of service p...

متن کامل

A Portable Embedded Data Acquisition and Communication System

The data acquisition equipment is very useful and popular equipment in agriculture and the other fields. This paper introduces the design of a portable data acquisition and communication system used in cropland. It collect signals of various analog and digital sensors, GPS space and time data, saving data by USB interface and transmission through WCDMA or Bluetooth. The key technology of the sy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies

دوره 8 6  شماره 

صفحات  -

تاریخ انتشار 2007