Unified resolution bounds for conventional and stochastic localization fluorescence microscopy.
نویسندگان
چکیده
Superresolution microscopy enables imaging in the optical far field with ~20 nm-scale resolution. However, classical concepts of resolution using point-spread and modulation-transfer functions fail to describe the physical limits of superresolution techniques based on stochastic localization of single emitters. Prior treatments of stochastic localization microscopy have defined how accurately a single emitter's position can be determined, but these bounds are restricted to sparse emitters, do not describe conventional microscopy, and fail to provide unified concepts of resolution for all optical methods. Here we introduce a measure of resolution, the information transfer function (ITF), that gives physical limits for conventional and stochastic localization techniques. The ITF bounds the accuracy of image determination as a function of spatial frequency and for conventional microscopy is proportional to the square of the modulation-transfer function. We use the ITF to describe how emitter density and photon counts affect imaging performance across the continuum from conventional to superresolution microscopy, without assuming emitters are sparse. This unified physical description of resolution facilitates experimental choices and designs of image reconstruction algorithms.
منابع مشابه
Improved localization accuracy in stochastic super-resolution fluorescence microscopy by K-factor image deshadowing.
Localization of a single fluorescent particle with sub-diffraction-limit accuracy is a key merit in localization microscopy. Existing methods such as photoactivated localization microscopy (PALM) and stochastic optical reconstruction microscopy (STORM) achieve localization accuracies of single emitters that can reach an order of magnitude lower than the conventional resolving capabilities of op...
متن کاملCluster Analysis of Super Resolution Fluorescence Images
Direct Stochastic Optical Reconstruction Microscopy (dSTORM) is a novel, high resolution technique to produce fluorescence images. It uses conventional organic fluorophores which are fluorescent molecules that emit light when excited in either a spontaneous or induced way. Common examples of fluorophores are labeled antibodies, used as markers to indicate locations of certain proteins. The fluo...
متن کاملEstimation theoretic measure of resolution for stochastic localization microscopy.
One approach to super-resolution fluorescence microscopy, termed stochastic localization microscopy, relies on the nanometer scale spatial localization of individual fluorescent emitters that stochastically label specific features of the specimen. The precision of emitter localization is an important determinant of the resulting image resolution but is insufficient to specify how well the deriv...
متن کاملReview of super-resolution fluorescence microscopy for biology.
Several methodologies have been developed over the past several years for super-resolution fluorescence microscopy including saturated structured-illumination microscopy (SSIM), stimulated emission depletion microscopy (STED), photoactivated localization microscopy (PALM), fluorescence photoactivation localization microscopy (FPALM), and stochastic optical reconstruction microscopy (STORM). Whi...
متن کاملSample drift correction in 3D fluorescence photoactivation localization microscopy.
The recent development of diffraction-unlimited far-field fluorescence microscopy has overcome the classical resolution limit of ~250 nm of conventional light microscopy by about a factor of ten. The improved resolution, however, reveals not only biological structures at an unprecedented resolution, but is also susceptible to sample drift on a much finer scale than previously relevant. Without ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Physical review letters
دوره 109 16 شماره
صفحات -
تاریخ انتشار 2012