Three dimensional first-pass myocardial perfusion imaging at 3T: feasibility study
نویسندگان
چکیده
BACKGROUND In patients with ischemic heart disease, accurate assessment of the extent of myocardial perfusion deficit may be important in predicting prognosis of clinical cardiac outcomes. The aim of this study was to compare the ability of three dimensional (3D) and of two dimensional (2D) multi-slice myocardial perfusion imaging (MPI) using cardiovascular magnetic resonance (CMR) in determining the size of defects, and to demonstrate the feasibility of 3D MPI in healthy volunteers at 3 Tesla. METHODS A heart phantom was used to compare the accuracy of 3D and 2D multi-slice MPI in estimating the volume fraction of seven rubber insets which simulated transmural myocardial perfusion defects. Three sets of cross-sectional planes were acquired for 2D multi-slice imaging, where each set was shifted along the partition encoding direction by +/- 10 mm. 3D first-pass contrast-enhanced (0.1 mmol/kg Gd-DTPA) MPI was performed in three volunteers with sensitivity encoding for six-fold acceleration. The upslope of the myocardial time-intensity-curve and peak SNR/CNR values were calculated. RESULTS Mean/standard deviation of errors in estimating the volume fraction across the seven defects were -0.44/1.49%, 2.23/2.97%, and 2.59/3.18% in 3D, 2D 4-slice, and 2D 3-slice imaging, respectively. 3D MPI performed in healthy volunteers produced excellent quality images with whole left ventricular (LV) coverage. Peak SNR/CNR was 57.6 +/- 22.0/37.5 +/- 19.7 over all segments in the first eight slices. CONCLUSION 3D performed better than 2D multi-slice MPI in estimating the size of perfusion defects in phantoms. Highly accelerated 3D MPI at 3T was feasible in volunteers, allowing whole LV coverage with excellent image quality and high SNR/CNR.
منابع مشابه
3 Tesla MR imaging provides improved contrast in first-pass myocardial perfusion imaging over a range of gadolinium doses.
PURPOSE To compare myocardial enhancement during first-pass myocardial perfusion imaging at 3.0 Tesla (T) and 1.5T. MATERIALS AND METHODS First-pass myocardial perfusion imaging was performed on twelve normal subjects at 3T and 1.5T using an interleaved notched saturation recovery gradient echo pulse sequence. Subjects received either 0.10 mmol/kg for both scans (group 1), 0.075 mmol/kg for b...
متن کاملOptimized Saturation Pulse Train for Human First-Pass Myocardial Perfusion Imaging at 7T
PURPOSE To investigate whether saturation using existing methods developed for 3T imaging is feasible for clinical perfusion imaging at 7T, and to propose a new design of saturation pulse train for first-pass myocardial perfusion imaging at 7T. METHODS The new design of saturation pulse train consists of four hyperbolic-secant (HS8) radiofrequency pulses, whose peak amplitudes are optimized f...
متن کاملThree-dimensional balanced steady state free precession myocardial perfusion cardiovascular magnetic resonance at 3T using dual-source parallel RF transmission: initial experience
BACKGROUND The purpose of this study was to establish the feasibility of three-dimensional (3D) balanced steady-state-free-precession (bSSFP) myocardial perfusion cardiovascular magnetic resonance (CMR) at 3T using local RF shimming with dual-source RF transmission, and to compare it with spoiled gradient echo (TGRE) acquisition. METHODS Dynamic contrast-enhanced 3D bSSFP perfusion imaging wa...
متن کاملSystolic 3D first-pass myocardial perfusion MRI
Introduction: First-pass myocardial perfusion imaging (MPI) is now an established tool for the assessment of ischemic heart disease, and the most widely used protocols involve 2D multi-slice acquisition. Three-dimensional (3D) MPI is potentially advantageous due to its contiguous spatial coverage and high SNR [1], and has been recently shown to be more accurate than 2D multi-slice techniques in...
متن کاملHyperpolarized C urea myocardial first- pass perfusion imaging using velocity- selective excitation
Background: A velocity-selective binomial excitation scheme for myocardial first-pass perfusion measurements with hyperpolarized C substrates, which preserves bolus magnetization inside the blood pool, is presented. The proposed method is evaluated against gadolinium-enhanced H measurements in-vivo. Methods: The proposed excitation with an echo-planar imaging readout was implemented on a clinic...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of Cardiovascular Magnetic Resonance
دوره 10 شماره
صفحات -
تاریخ انتشار 2008