Surface plasmon resonance biosensor with high anti-fouling ability for the detection of cardiac marker troponin T.
نویسندگان
چکیده
Designing a surface recognition layer with high anti-fouling ability, high affinity, and high specificity is an important issue to produce high sensitivity biosensing transducers. In this study, a self-assembled monolayer (SAM) consisting of a homogeneous mixture of oligo(ethylene glycol) (OEG)-terminated alkanethiolate and mercaptohexadecanoic acid (MHDA) on Au was employed for immobilizing troponin T antibody and applied in detecting cardiac troponin T by using surface plasmon resonance (SPR). The mixed SAM showed no phase segregation and exhibited human serum albumin resistance, particularly with an antibody-immobilized surface. X-ray photoemission spectra revealed that the chemical composition ratio of OEG to the mixed SAM was 69% and the OEG packing density was 82%. The specific binding of troponin T on the designed surface indicated a good linear correlation (R=0.991, P<0.0009) at concentrations lower than 50 μgmL(-1) with the limit of detection of 100 ngmL(-1) using a SPR measuring instrument. It is concluded that the mixed SAM functions as designed since it has high detection capability, high accuracy and reproducibility, as well as shows strong potential to be applied in rapid clinical diagnosis for label-free detection within 2 min.
منابع مشابه
Antibody Conjugated Gold Nanoparticles for Detection of Small Amounts of Antigen Based on Surface Plasmon Resonance (SPR) Spectra
In this paper, a fast and sensitive localized surface plasmon resonance (LSPR) based biosensor was developed and the optimization of gold – antibody conjugates through investigation of different parameters were performed. Gold nanoparticles (AuNPs) with a size of ~20 nm were synthesized via chemical reduction of HAuCl4 with trisodium citrate as reducing and stabilizing agent. The impacts of pH ...
متن کاملAchieving biosensing at attomolar concentrations of cardiac troponin T in human biofluids by developing a label-free nanoplasmonic analytical assay.
Acute myocardial infarction (heart attack) is the fifth leading cause of death in the United States (Dariush et al., Circulation, 2015, 131, e29-e322). This highlights the need for early, rapid, and sensitive detection of its occurrence and severity through assaying cardiac biomarkers in human fluids. Herein we report chip-based fabrication of the first label-free, nanoplasmonic biosensor to as...
متن کاملAn Aptamer-based Biosensor for Troponin I Detection in Diagnosis of Myocardial Infarction
Background: Acute myocardial infarction (MI) accounts for one third of deaths. Cardiac troponin I (TnI) is a reliable biomarker of cardiac muscle tissue injury and is employed in the early diagnosis of MI.Objectives: In this study, a molecular method is introduced to early diagnosis of MI by rapid detection of TnI.Materials and Methods: The detection method was based on electrochemical aptasens...
متن کاملMonitoring of troponin release from cardiomyocytes during exposure to toxic substances using surface plasmon resonance biosensing.
Troponin T (TnT) is a useful biomarker for studying drug-induced toxicity effects on cardiac cells. We describe how a surface plasmon resonance (SPR) biosensor was applied to monitor the release of TnT from active HL-1 cardiomyocytes in vitro when exposed to cardiotoxic substances. Two monoclonal human TnT antibodies were compared in the SPR immunosensor to analyse the TnT release. The detectio...
متن کاملDetection of Carcinoembryonic Antigens Using a Surface Plasmon Resonance Biosensor
Carcinoembryonic antigen (CEA) is an oncofoetal cell-surface glycoprotein that serves as an important tumor marker for colorectal and some other carcinomas. In this work, a CEA immunoassay using a surface plasmon resonance (SPR) biosensor has been developed. SPR could provide label-free, real-time detection with high sensitivity, though its ability to detect CEA in human serum was highly depend...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Analytica chimica acta
دوره 703 1 شماره
صفحات -
تاریخ انتشار 2011