A two-short-implant-supported molar restoration in atrophic posterior maxilla: A finite element analysis

نویسندگان

  • Ho-Yong Song
  • Yoon-Hyuk Huh
  • Chan-Jin Park
  • Lee-Ra Cho
چکیده

PURPOSE The aim of this study was to investigate the stress distribution of 2-short implants (2SIs) installed in a severely atrophic maxillary molar site. MATERIALS AND METHODS Three different diameters of internal connection implants were modeled: narrow platform (NP), regular platform (RP), and wide platform (WP). The maxillary first molars were restored with one implant or two short implants. Three 2SI models (NP-oblique, NP-vertical, and NP-horizontal) and four single implant models (RP and WP in a centered or cantilevered position) were used. Axial and oblique loadings were applied on the occlusal surface of the crown. The von Mises stress values were measured at the bone-implant, peri-implant bone, and implant/abutment complex. RESULTS The highest stress distribution at the bone-implant interface and the peri-implant bone was noticed in the RP group, and the lowest stress distribution was observed in the 2SI groups. Cantilevered position showed unfavorable stress distribution with axial loading. 2SI types did not affect the stress distribution in oblique loading. The number and installation positions of the implant, rather than the bone level, influenced the stress distribution of 2SIs. The implant/abutment complex of WP presented the highest stress concentration while that of 2SIs showed the lowest stress concentration. CONCLUSION 2SIs may be useful for achieving stable stress distribution on the surrounding bone and implant-abutment complex in the atrophic posterior maxilla.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Outcome of short implants as an alternative to sinus lift surgery and standard-length implants for rehabilitation of atrophic posterior maxilla: A clinical trial

Background and Aims: The aim of this study was to assess the outcome of short implants (<8 mm length) as an alternative to sinus lift surgery and placement of standard-length implants (10-12 mm length) for rehabilitation of atrophic posterior maxilla. Materials and Methods: In this prospective clinical trial, 26 patients with 6-7 mm of residual alveolar bone height in their atrophic posterior ...

متن کامل

A Two-step Method for the Preparation of Implant Recipient Site in Severe Atrophic Maxilla: A Case Report of the Alveolar Ridge Split Technique Followed by Bone Expansion

Augmentation of deficient and atrophic alveolar ridges is an important aspect of dental implant therapy with the goal of providing a functional restoration in harmony with adjacent natural dentition. Bone splitting technique is considered a distinguished augmentation method for treatment of deficient alveolar ridges. According to this procedure, the compromised alveolar ridge is opened from the...

متن کامل

Influence of crown-to-implant ratio, retention system, restorative material, and occlusal loading on stress concentrations in single short implants.

PURPOSE The aim of this study was to assess the contributions of some prosthetic parameters such as crown-to-implant (C/I) ratio, retention system, restorative material, and occlusal loading on stress concentrations within a single posterior crown supported by a short implant. MATERIALS AND METHODS Computer-aided design software was used to create 32 finite element models of an atrophic poste...

متن کامل

Angulated Dental Implants in Posterior Maxilla FEA and Experimental Verification

AIM This study aimed to evaluate the effect of different implant angulations in posterior maxilla on stress distribution by finite element analysis and verify its results experimentally. METHODS Two simplified models were prepared for an implant placed vertically and tilted 25° piercing the maxillary sinus. Geometric models' components were prepared by Autodesk Inventor then assembled in ANSY...

متن کامل

تعیین توزیع تنش استخوان اطراف ایمپلنت‌های فک پایین در طرح‎های مختلف پروتز به هنگام Mandibular- Flexure

Statement of Problem: In the treatment of edentulous patients with implant supported fixed partial dentures several factors such as implant numbers, implant position, superstructure pattern and cantilever length must be considered. Mandibular flexture in function exerts forces in peri-implant bone, however this phenomenon has received little attention. Purpose: The goal of this finite element a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2016