Error correction and quantitative subanalysis of optical coherence tomography data using computer-assisted grading.

نویسندگان

  • Srinivas R Sadda
  • Sandra Joeres
  • Ziqiang Wu
  • Paul Updike
  • Peggy Romano
  • Allyson T Collins
  • Alexander C Walsh
چکیده

PURPOSE To demonstrate feature subanalysis and error correction of optical coherence tomography (OCT) data by using computer-assisted grading. METHODS The raw exported StratusOCT (Carl Zeiss Meditec, Inc., Dublin, CA) scan data from 20 eyes of 20 patients were analyzed using custom software (termed OCTOR) designed to allow the user to define manually the retinal borders on each radial line scan. Measurements calculated by the software, including thickness of the nine standard macular subfields, foveal center point (FCP), and macular volume, were compared between two graders and with the automated Stratus analysis. Mean and range of differences for each parameter were calculated and assessed by Bland-Altman plots and Pearson correlation coefficients. Additional cases with clinically relevant subretinal findings were selected to demonstrate the capabilities of this system for quantitative feature subanalysis. RESULTS Retinal thickness measurements for the various subfields and the FCP showed a mean difference of 1.7 mum (maximum, 7 microm) between OCTOR graders and a mean difference of 2.3 microm (maximum of 8 microm) between the OCTOR and Stratus analysis methods. Volume measurements between Stratus and OCTOR methods differed by a mean of 0.06 mm(3) (in reference to a mean macular volume of 6.81 mm(3)). The differences were not statistically significant, and the thicknesses correlated highly (R(2) > or = 0.98 for all parameters). CONCLUSIONS Manual identification of the inner and outer retinal boundaries on OCT scans can produce retinal thickness measurements consistent with those derived from the automated StratusOCT analysis. Computer-assisted OCT grading may be useful for correcting thickness measurements in cases with errors of automated retinal boundary detection and may be useful for quantitative subanalysis of clinically relevant features, such as subretinal fluid volume or pigment epithelial detachment volume.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reproducibility of quantitative optical coherence tomography subanalysis in neovascular age-related macular degeneration.

PURPOSE To determine the intergrader reproducibility for computer-assisted grading of optical coherence tomography (OCT) images in eyes with neovascular age-related macular degeneration (AMD), by using a standardized grading procedure. METHODS Sixty OCT image sets (of six radial lines each) were independently analyzed by two graders using validated custom software (OCTOR) to draw boundaries m...

متن کامل

Improving image segmentation performance and quantitative analysis via a computer-aided grading methodology for optical coherence tomography retinal image analysis.

We demonstrate quantitative analysis and error correction of optical coherence tomography (OCT) retinal images by using a custom-built, computer-aided grading methodology. A total of 60 Stratus OCT (Carl Zeiss Meditec, Dublin, California) B-scans collected from ten normal healthy eyes are analyzed by two independent graders. The average retinal thickness per macular region is compared with the ...

متن کامل

The Application of Multi-Layer Artificial Neural Networks in Speckle Reduction (Methodology)

Optical Coherence Tomography (OCT) uses the spatial and temporal coherence properties of optical waves backscattered from a tissue sample to form an image. An inherent characteristic of coherent imaging is the presence of speckle noise. In this study we use a new ensemble framework which is a combination of several Multi-Layer Perceptron (MLP) neural networks to denoise OCT images. The noise is...

متن کامل

Feasibility Assessment of Optical Coherence Tomography-Guided Laser Labeling in Middle Cranial Fossa Approach

Introduction: Different approaches have been developed to find the position of the internal auditory canal (IAC)in middle cranial fossa approach. A feasibility study was performed to investigate the combination of cone beam computed tomography (CBCT), optical coherence tomography (OCT), and laser ablation to assist a surgeon in a middle cranial fossa approach by outlining the internal auditory ...

متن کامل

Clinical Applications of Optical Coherence Tomography in Ophthalmology

Assessment of the peripapillary nerve fiber layer and macular thickness can be determined in ophthalmology using optical coherence tomography (OCT). Decreased nerve fiber layer thickness and macular ganglion cell thickness in optic nerve ischemia have been correlated with visual field loss. OCT allows deep optic nerve head evaluation which helps understand pathophysiology of diseases.  Furtherm...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 48 2  شماره 

صفحات  -

تاریخ انتشار 2007