Self-expanding versus balloon-mounted stents for vessel recanalization following embolic occlusion in the canine model: technical feasibility study.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Despite advances in mechanical thrombolysis for acute stroke, recanalization rates remain approximately 50%-60%. Technologic improvements allowed safe intracranial delivery of stents. To study the feasibility of stent-assisted recanalization for acute stroke, we deployed self-expanding or balloon-mounted stents in 2- to 3.5-mm canine vessels acutely occluded with clot emboli. METHODS Six mongrel dogs were placed under general anesthesia. A guiding catheter was placed in the distal vertebral artery or an external carotid artery branch. A 7 x 3 mm (length x diameter) soft or hard clot was injected into the catheter and allowed to embolize distally; 20 vessels were successfully occluded. After systemic heparin anticoagulation, recanalization with a self-expanding stent was attempted in 11 vessels (5 occluded with soft clot; 6, with hard clot). Balloon-mounted stents were placed in an attempt to revascularize 9 vessels (4 occluded with soft clot; 5, with hard clot). Vessel recanalization was assessed as the primary end point. Side-branch occlusion and stent-induced vasospasm were also assessed. RESULTS Thrombolysis in Myocardial Infarction/Thrombolysis in Cerebral Infarction flow for 11 vessels treated with self-expanding stents versus 9 treated with balloon-mounted stents was as follows: grade 3, 91% of vessels versus 78% of vessels; grade 2, 0% versus 11%; grade 1, 9% versus 0%; grade 0, 0% versus 11%. Lower rates of spasm and side-branch occlusion were noticed with self-expanding stents. Grade 2/3 flow was achieved in 18/20 vessels (90%). CONCLUSIONS Excellent recanalization was demonstrated with both stents. Recanalization in self-expanding stents was achieved without pre- or post-balloon dilation. Stents may prove to be a useful adjunct for intra-arterial acute stroke treatment.
منابع مشابه
Self-expanding stents for recanalization of acute cerebrovascular occlusions.
BACKGROUND AND PURPOSE Stent-assisted revascularization increases prevailing recanalization rates ( congruent with 50%-69%) for vessel occlusions recalcitrant to thrombolytics. Although balloon-mounted coronary stents can displace thrombus (via angioplasty) and retain clot along vessel walls, intracranial self-expanding stents are more flexible and exert less radial outward force during deploym...
متن کاملPercutaneous transluminal angioplasty and stent placement in acute vessel occlusion: evaluation of new methods for interventional stroke treatment.
BACKGROUND AND PURPOSE The major goal of acute ischemic stroke treatment is fast and sufficient recanalization. Percutaneous transluminal balloon angioplasty (PTA) and/or placement of a stent might achieve both by compressing the thrombus at the occlusion site. This study assesses the feasibility, recanalization rate, and complications of the 2 techniques in an animal model. MATERIALS AND MET...
متن کاملSelf-expanding and balloon-expandable stents in the treatment of carotid aneurysms: an experimental study in a canine model.
PURPOSE To assess the efficacy of metal stents for the treatment of different forms and sizes of carotid aneurysms. METHODS A total of 14 experimentally constructed aneurysms in dogs were treated with transfemorally placed balloon-expandable tantalum and self-expanding nitinol stents. RESULTS In 10 cases, stenting produced either immediate complete occlusion of the aneurysm (n = 7) or compl...
متن کاملStent placement in acute cerebral artery occlusion: use of a self-expandable intracranial stent for acute stroke treatment.
BACKGROUND AND PURPOSE Stent placement has been applied in small case series as a rescue therapy in combination with different thrombolytic agents, percutaneous balloon angioplasty (PTA), and mechanical thromboembolectomy (MT) in acute stroke treatment. These studies report a considerable mortality and a high rate of intracranial hemorrhages when balloon-mounted stents were used. This study was...
متن کاملSelf-expanding stent for recanalization of acute embolic or dissecting intracranial artery occlusion.
BACKGROUND AND PURPOSE Stent placement may be an effective and last resort method for recanalization of recalcitrant intracranial artery occlusion. The purpose of this study was to evaluate the safety and efficacy of a self-expanding stent for the recanalization of acute embolic or dissecting intracranial artery occlusion. MATERIALS AND METHODS Nine patients (mean age, 66 years; NIHSS score, ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 27 10 شماره
صفحات -
تاریخ انتشار 2006