Impact of Platelet-Rich Plasma on Arthroscopic Repair of Small- to Medium-Sized Rotator Cuff Tears

نویسندگان

  • Richard Holtby
  • Monique Christakis
  • Eran Maman
  • Joy C. MacDermid
  • Tim Dwyer
  • George S. Athwal
  • Kenneth Faber
  • John Theodoropoulos
  • Linda J. Woodhouse
  • Helen Razmjou
چکیده

BACKGROUND Increased interest in using platelet-rich plasma (PRP) as an augment to rotator cuff repair warrants further investigation, particularly in smaller rotator cuff tears. PURPOSE To examine the effectiveness of PRP application in improving perioperative pain and function and promoting healing at 6 months after arthroscopic repair of small- or medium-sized rotator cuff tears. STUDY DESIGN Randomized controlled trial; Level of evidence, 1. METHODS This was a double-blinded randomized controlled trial of patients undergoing arthroscopic repair of partial- or full-thickness rotator cuff tears of up to 3 cm who were observed for 6 months. Patients were randomized to either repair and PRP application (study group) or repair only (control group) groups. The patient-oriented outcome measures utilized were the visual analog scale (VAS), the Short Western Ontario Rotator Cuff Index (ShortWORC), the American Shoulder and Elbow Surgeons (ASES) form, and the Constant-Murley Score (CMS). Range of motion (ROM) and inflammatory and coagulation markers were measured before and after surgery. Magnetic resonance imaging was used at 6 months to assess retear and fatty infiltration rate. RESULTS Eighty-two patients (41 males) with a mean age of 59 ± 8 years were enrolled; 41 patients were included in each group. Both the PRP and control groups showed a significant improvement in their pain level based on the VAS within the first 30 days (P < .0001), with the PRP group reporting less pain than the control group (P = .012), which was clinically significantly different from days 8 through 11. The PRP group reported taking less painkillers (P = .026) than the control group within the first 30 days. All outcome measure scores and ROM improved significantly after surgery (P < .0001), with no between-group differences. No differences were observed between groups in inflammatory or coagulation marker test results (P > .05), retear (14% vs 18% full retear; P = .44), or fatty infiltration rate (P = .08). CONCLUSION The PRP biological augmentation for repair of small- to medium-sized rotator cuff tears has a short-term effect on perioperative pain without any significant impact on patient-oriented outcome measures or structural integrity of the repair compared with control group.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Efficacy of platelet-rich plasma in arthroscopic repair of full-thickness rotator cuff tears: a meta-analysis.

BACKGROUND The use of platelet-rich plasma (PRP) is an innovative clinical therapy, especially in arthroscopic rotator cuff repair. The purpose of this study was to compare the clinical improvement and tendon-to-bone healing with and without PRP therapy in arthroscopic rotator cuff repair. METHODS A systematic search was done in the major medical databases to evaluate the studies using PRP th...

متن کامل

Clinical Results of Platelet-Rich Plasma for Partial Thickness Rotator Cuff Tears: A Case Series

Partial thickness rotator cuff tears (PTRCTs) are a common pathology among shoulder disorders in people over 50 years.Treatment of PTRCTs remains controversial. Most studies on the treatment of PTRCTs have explained surgical techniquesor outcomes; few studies have centralized on the conservative and new management of PTRCTs, like treatmentwith Platelet-rich plasma (PRP). These case series study...

متن کامل

Are Platelet-Rich Products Necessary during the Arthroscopic Repair of Full-Thickness Rotator Cuff Tears: A Meta-Analysis

BACKGROUND Platelet-rich products (PRP) are widely used for rotator cuff tears. However, whether platelet-rich products produce superior clinical or radiological outcomes is controversial. This study aims to use meta-analysis to compare clinical and radiological outcomes between groups with or without platelet-rich products. METHODS The Pubmed, Embase, and Cochrane library databases were sear...

متن کامل

Platelet-rich plasma augmentation for arthroscopic rotator cuff repair: a randomized controlled trial.

BACKGROUND After reinsertion on the humerus, the rotator cuff has limited ability to heal. Growth factor augmentation has been proposed to enhance healing in such procedure. PURPOSE This study was conducted to assess the efficacy and safety of growth factor augmentation during rotator cuff repair. STUDY DESIGN Randomized controlled trial; Level of evidence, 1. METHODS Eighty-eight patient...

متن کامل

Preliminary Results of a Consecutive Series of Large & Massive Rotator Cuff Tears Treated with Arthroscopic Rotator Cuff Repairs Augmented with Extracellular Matrix

 Background: Recurrence rate of rotator cuff tears is still high despite the improvements of surgical techniques, materials used and a better knowledge of the healing process of the rotator cuff tendons. Large to massive rotator cuff tears are particularly associated with a high failure rate, especially in elderly. Augmentation of rotator cuff repairs with extracellular matrix or synthetic patc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2016