Uses and abuses of EIDORS: an extensible software base for EIT.
نویسندگان
چکیده
EIDORS is an open source software suite for image reconstruction in electrical impedance tomography and diffuse optical tomography, designed to facilitate collaboration, testing and new research in these fields. This paper describes recent work to redesign the software structure in order to simplify its use and provide a uniform interface, permitting easier modification and customization. We describe the key features of this software, followed by examples of its use. One general issue with inverse problem software is the difficulty of correctly implementing algorithms and the consequent ease with which subtle numerical bugs can be inadvertently introduced. EIDORS helps with this issue, by allowing sharing and reuse of well-documented and debugged software. On the other hand, since EIDORS is designed to facilitate use by non-specialists, its use may inadvertently result in such numerical errors. In order to address this issue, we develop a list of ways in which such errors with inverse problems (which we refer to as 'cheats') may occur. Our hope is that such an overview may assist authors of software to avoid such implementation issues.
منابع مشابه
Simple FEMs aren’t as good as we thought: experiences developing EIDORS v3.3
In this paper, we 1: announce EIDORS version 3.3, and clarify the new features and changes to the software. Briefly, the new version includes: a) interfaces to FEM generation (distmesh, netgen) and dual model solvers, b) new algorithms (total variation, electrode movement solver, temporal solvers), c) a data repository with in vivo and simulated data and models, d) faster algorithms with better...
متن کاملElectrical Impedance Tomography (EIT) and Its Medical Applications: A Review
This paper reviews the principles of Electrical Impedance Tomography (EIT), different types of current patterns and reconstruction algorithms to assess its potential in medical imaging. A current injection pattern in EIT has its own current distribution profile within the subject under test. Hence, different current patterns have different sensitivity, spatial resolution and distinguishability....
متن کاملElectrical Impedance Tomography (eit) Method for Saturation Determination
3D Electrical Impedance Tomography (EIT) is an alternative to the traditional CT scan technique that has been used to measure saturation distribution within a rock core. The primary motivation for investigating EIT is the applicability to high pressure, high temperature geothermal reservoir conditions, which would require a metal core holder, therefore eliminating the use of the CT scan techniq...
متن کاملFinite element meshes with electrode refinement in EIDORS
MOTIVATION: The accuracy of solutions to partial differential equations (PDE) obtained with the finite element method (FEM) depends on appropriate choice of domain discretization. The elements must be smaller than the smallest features which may occur in the solution. On the other hand, small elements increase the size of the FEM and hence the amount of computational time and memory required to...
متن کاملAddressing the computational cost of large EIT solutions.
Electrical impedance tomography (EIT) is a soft field tomography modality based on the application of electric current to a body and measurement of voltages through electrodes at the boundary. The interior conductivity is reconstructed on a discrete representation of the domain using a finite-element method (FEM) mesh and a parametrization of that domain. The reconstruction requires a sequence ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Physiological measurement
دوره 27 5 شماره
صفحات -
تاریخ انتشار 2006