Eye shape in emmetropia and myopia.

نویسندگان

  • David A Atchison
  • Catherine E Jones
  • Katrina L Schmid
  • Nicola Pritchard
  • James M Pope
  • Wendy E Strugnell
  • Robyn A Riley
چکیده

PURPOSES To determine axial, vertical, and horizontal eye dimensions in myopic and emmetropic eyes by using magnetic resonance imaging (MRI) and to relate these to different ocular expansion models of myopia development. METHODS The internal length (cornea to retina), height and width (both retina to retina) were measured in emmetropic and myopic eyes (up to -12 D) of 88 participants aged 18 to 36 years. Participants were positioned supine in a clinical MRI scanner. The fixation target was imaged straight ahead of the subject by an overhead 45 degrees inclined mirror. Eye images were acquired with a 7.5-cm receive-only radio frequency surface coil. Axial (horizontal through middle of eye) and sagittal (vertical through visual axis) sections were taken with a T(1)-weighted fast spin-echo sequence. RESULTS With an increase in myopic refractive correction, myopic eyes became much larger in all three dimensions, but more so in length (0.35 mm/D, 95% confidence interval [CI] 0.28-0.40) than in height (0.19 mm/D, 95% CI 0.09-0.29) and more so in height than in width (0.10 mm/D, 95% CI 0.01-0.20). Based on height and length dimensions, 25% and 29% of myopic eyes exclusively fitted global expansion and axial elongation models, respectively. Based on width and length dimensions, 17% and 39% of myopic eyes exclusively fitted the global expansion and axial elongation models, respectively. CONCLUSIONS Although there are considerable individual variations, in general myopic eyes are elongated relative to emmetropic eyes, more in length than in height and even less in width. Approximately a quarter of the myopic participants fitted each of the global expansion or axial elongation model exclusively. The small proportions are due primarily to the large variability in the dimensions of emmetropic eyes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

More irregular eye shape in low myopia than in emmetropia.

PURPOSE To improve the description of the peripheral eye shape in myopia and emmetropia by using a new method for continuous measurement of the peripheral refractive state. METHODS A scanning photorefractor was designed to record refractive errors in the vertical pupil meridian across the horizontal visual field (up to +/-45 degrees ). The setup consists of a hot mirror that continuously proj...

متن کامل

The regulation of eye growth and refractive state: an experimental study of emmetropization.

During growth the vertebrate eye achieves a close match between the power of its optics and its axial length with the result that images are focused on the retina without accommodative effort (emmetropia). The possibility that vision is required for the regulation of eye growth was studied experimentally in chicks made myopic or hyperopic by different visual manipulations. After discontinuing t...

متن کامل

Relations between Age, Weight, Refractive Error and Eye Shape by Computerized Tomography in Children

PURPOSE To investigate relationships between age, weight, refractive error, and morphologic changes in children's eyes by computerized tomography (CT). METHODS Of the 772 eyes of 386 patients under the age of 20 years, who visited our Department of Ophthalmology between January 2005 to August 2006 and underwent CT of the orbit, 406 eyes of 354 patients with clear CT images and normal eyeball ...

متن کامل

Association between Myopia, Biometry and Occludable Angle: The Jiangning Eye Study

BACKGROUND Myopia subjects usually have long axial lengths and are predisposed to deep anterior chamber depths and open angles. Jiangning eye study is a randomized, population based study in Shanghai to determine whether myopia has an effect on the prevalence of occludable angles. METHODS A total of 2478 residents aged 50 years and over were randomly selected, and 2044 (82.5%) individuals of ...

متن کامل

Choroidal Thickness Variation According to Refractive Error Measured by Spectral Domain-optical Coherence Tomography in Korean Children

PURPOSE To assess choroidal thickness (CT) variation according to refractive errors using enhanced-depth imaging optical coherence tomography. METHODS Eighty-nine eyes (in 89 children) <±6 diopter were categorized into three groups: hyperopia, emmetropia, and myopia, according to refractive error, and underwent choroidal scans using enhanced-depth imaging-optical coherence tomography. CT was ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 45 10  شماره 

صفحات  -

تاریخ انتشار 2004