Patient-Specific Instruments Based on Knee Joint Computed Tomography and Full-Length Lower Extremity Radiography in Total Knee Replacement

نویسندگان

  • Hua Tian
  • Min-Wei Zhao
  • Xiao Geng
  • Qi-Yun Zhou
  • Yang Li
چکیده

Background Restoring good alignment after total knee replacement (TKR) is still a challenge globally, and the clinical efficiency of patient-specific instruments (PSIs) remains controversial. In this study, we aimed to explore the value and significance of three-dimensional printing PSIs based on knee joint computed tomography (CT) and full-length lower extremity radiography in TKR. Methods Between June 2013 and October 2014, 31 TKRs were performed using PSIs based on knee joint CT and full-length lower extremity radiography in 31 patients (5 males and 26 females; mean age: 67.6 ± 7.9 years; body mass index [BMI]: 27.4 ± 3.5 kg/m2). Thirty-one matched patients (4 males and 27 females; mean age: 67.4 ± 7.2 years; mean BMI: 28.1 ± 4.6 kg/m2) who underwent TKR using conventional instruments in the same period served as the control group. The mean follow-up period was 38 months (31-47 months). Knee Society Score (KSS), surgical time, and postoperative drainage volume were recorded. Coronal alignment was measured on full-length radiography. Results Twenty-three (74.2%) and 20 (64.5%) patients showed good postoperative alignment in the PSI and control groups, respectively, without significant difference between the two groups (χ2 = 0.68, P = 0.409). The mean surgical time was 81.48 ± 16.40 min and 72.90 ± 18.10 min for the PSI and control groups, respectively, without significant difference between the two groups (t = 0.41, P = 0.055). The postoperative drainage volume was 250.9 ± 148.8 ml in the PSI group, which was significantly less than that in the control group (602.1 ± 230.6 ml, t = 6.83, P < 0.001). No significant difference in the KSS at the final follow-up was found between the PSI and control groups (91.06 ± 3.26 vs. 90.19 ± 3.84, t = 0.95, P = 0.870). Conclusions The use of PSIs based on knee joint CT and standing full-length lower extremity radiography in TKR resulted in acceptable alignment compared with the use of conventional instruments, although the marginal advantage was not statistically different. Surgical time and clinical results were also similar between the two groups. However, the PSI group had less postoperative drainage.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Approach to Developing Customized Total Knee Replacement Implants

Total knee replacement (TKR) has been performed for patients with end-stage knee joint arthritis to relieve pain and gain functions. Most knee replacement patients can gain satisfactory knee functions; however, the range of motion of the implanted knee is variable. There are many designs of TKR implants; it has been suggested by some researchers that customized implants could offer a better opt...

متن کامل

Comparison of Clinical, Functional, and Radiological Outcomes of Total Knee Arthroplasty Using Conventional and Patient-Specific Instrumentation

Background: Recently, patient-specific instrumentation (PSI) systems have been developed in order to increase theaccuracy of component positioning during total knee arthroplasty (TKA); however, the findings of previous studies arecontroversial in this regard. In the current randomized clinical study, the outcomes of computer tomography (CT)-basedPS (patient specific)-guided TK...

متن کامل

Component alignment during total knee arthroplasty with use of standard or custom instrumentation: a randomized clinical trial using computed tomography for postoperative alignment measurement.

BACKGROUND Patient-specific femoral and tibial cutting blocks produced with use of data from preoperative computed tomography (CT) or magnetic resonance imaging (MRI) scans have been employed recently to optimize component alignment in total knee arthroplasty. We report the results of a randomized controlled trial in which CT scans were used to compare postoperative component alignment between ...

متن کامل

Relationship between Femoral Intercondylar Notch Narrowing on Radiography and Anatomical and Histopathologic Integrity of Anterior Cruciate Ligament in Patients Undergoing Total Knee Replacement Surgery

Abstract Introduction: The presence of cruciate ligaments are very important for normal knee kinematics. Knee arthroplasty prostheses, in which these ligaments are maintained, have better kinematics. The aim of the present study was to investigate the association between femoral intercondylar notch narrowing in radiography and clinical and histopathologic integrity of anterior cruciate li...

متن کامل

Analysis of the Geometry of the Distal Femur and Proximal Tibia in the Osteoarthritic Knee: A 3D Reconstruction CT Scan Based Study of 449 Cases

    Background: The aim of this study is to evaluate the geometry of the distal femur and the proximal tibia in the osteoarthritic knee using 3D reconstructive CT scan imaging. Methods: 449 patients with knee osteoarthritis were treated surgically in our center with patient-specific technology total knee arthroplasty. Preoperatively, all the patients underwent a CT scan according to a standard ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 131  شماره 

صفحات  -

تاریخ انتشار 2018